5 - 3
5-2 PLL UNIT ADJUSTMENT
LPL LOCK
VOLTAGE
HPL LOCK
VOLTAGE
REFERENCE
FREQUENCY
1
2
1
2
1
2
• Operating frequency : 0.5000 MHz
• Mode
: J3E
• Receiving
• Operating frequency : 0.4999 MHz
• Receiving
• Operating frequency : 29.9999 MHz
• Mode
: J3E
• Receiving
• Operating frequency : 0.0300 MHz
• Receiving
• Wait for 5 minutes after power ON.
• Terminate P5201 on the PLL unit to
ground with a 50
Ω
resister.
• Receiving
PLL
PLL
PLL
Connect a digital multi
meter or oscilloscope
to the check point
CP5301.
Connect a digital multi
meter or oscilloscope
to the check point
CP5401.
Connect an RF volt-
meter to the check
point P5201.
Connect a frequency
counter to the check
point P5201.
1.0 V
Less than 4.0 V
4.2 V
More than 0.8 V
Maximum level
64.000000 MHz
PLL
PLL
PLL
C5305
Verify
C5521
Verify
L5203,
L5204
R5255
ADJUSTMENT
ADJUSTMENT CONDITIONS
UNIT
LOCATION
VALUE
UNIT
ADJUST
MEASUREMENT
ADJUSTMENT
Содержание IC-F7000
Страница 1: ...HF TRANSCEIVER iF7000 SERVICE MANUAL ...
Страница 61: ... BOTTOM VIEW MAIN UNIT 9 8 ...
Страница 63: ... BOTTOM VIEW PA UNIT 9 10 ...
Страница 65: ...1 4 8 1 4 8 5 5 9 12 BOTTOM VIEW PLL UNIT ...
Страница 66: ...9 3 5 DRIVER BOARD TOP VIEW 9 13 GND VARO VARI to PA unit J6411 9 3 6 VARISTOR 1 BOARD ...
Страница 78: ......
Страница 79: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14012HZ C1 C 2003 Icom Inc ...