6 - 1
SECTION 6. ADJUSTMENT
PROCEDURE
Modulation analyzer
(DC measurable)
Attenuator
50 dB or 60 dB
to the antenna connector
to DC cable
Standard signal generator
–127 to –17 dBm
(0.1 V to 32 mV)
CAUTION:
DO NOT
transmit while
SSG is connected to
the antenna connector.
RF power meter
60 W
DC power supply
13.6 V / 20 A
Frequency
counter
Oscilloscope
AC millivoltmeter
Audio generator
to the MIC
connector
JIG CABLE
to USB port
PC
M
CONNECTION
M
JIG CABLE
6-1 PREPARATION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Cloning Software
CS-F3210D/
F3230D/F5220D
: Revision 1.0 or later
JIG Cable
Modifi ed OPC-1122U (see the illust below)
DC Power Supply
Output voltage
Current capacity
: 13.6 V DC
: More than 20 A
Attenuator
Power attenuation
Capacity
: 50 or 60 dB
: 60 W or more
Modulation
Analyzer
Frequency range
Measuring range
: DC–600 MHz
: 0 to
±
10 kHz
External Speaker
Input impedance
Capacity
: 4
Ω
: 20 W or more
Frequency Counter
Frequency range
Frequency accuracy
Sensitivity
: 0.1–600 MHz
: ±1 ppm or better
: 100 mV or better
Standard Signal
Generator (SSG)
Frequency range
Output level
: 0.1–600 MHz
: 0.1 µV to 32 mV
(–127 to –17 dBm)
RF Power Meter
Measuring range
Frequency range
Impedance
SWR
: 0.1–60 W
: 100–600 MHz
: 50
Ω
: Better than 1.2 : 1
Oscilloscope
Frequency rang
Measuring range
: DC–20 MHz
: 0.01–20 V
Add a jumper wire here
OPC-1122U
+
GND
MIC
PTT
GND
GND
SP
PTT SWITCH
+ −
AC MILLIVOLTMETER
(10 mV to 10 V)
AUDIO GENERATOR
(300–3000 Hz/1–500 mV)
+ −
+
−
4.7 µF
EXT. SPEAKER
(5 W/4
Ω)
SETTING;
Frequency : 1 kHz
Level
: 40 mVrms
Waveform : Sine wave