5 - 11
ADJUSTMENT
[ADJUST ITEM]
ADJUSTMENT CONDITION
OPERATION
VALUE
S-METER
[S-METER]
(S6 LEVEL)
NOTE:
“RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not
be adjusted properly.
1 •
•
•
•
Channel :
1-14
Connect a Standard Signal Generator to the
antenna connector.
Set the SSG output level to “+13 dBµ (–94 dBm).”
Receiving
Push the return key to set the S6
level.
(Automatic
adjustment)
[S-METER]
(S1 LEVEL)
2 •
•
Set the SSG output level to “–12 dBµ (–119 dBm).”
Receiving
Push the return key to set the S1
level.
5-4 RECEIVE ADJUSTMENT (continued)
Select an adjustment item using [
↑
] / [
↓
] keys, then set to the specifi ed value using [
←
] / [
→
] keys on the connected PC’s keyboard.
STANDARD SIGNAL GENERATOR
(1–300 MHz)
SETTING;
Modulation : 1 kHz
Deviation :
3.5
kHz
Level
: +13 dBµ (S6 level)
−12 dBµ (S1 level)
CAUTION:
DO NOT
transmit while
an SSG is connected to
the antenna connector.