TRANSMITTER ADJUSTMENT for IC-F4TR
UNIT
LOCATION
UNIT ADJUST
FM
1 Operating freq:
Top
Connect an FM devia-
Set to
MAIN
R119
BALANCE
500.000 MHz
panel tion meter to the an-
flat wave
tenna connector thro-
gh an attenuator.
FM
1 Operating freq:
Top
Connect an FM devia-
3.5kHz
MAIN R564
DEVIATION
500.000 MHz
panel tion meter to the
Wide/Narrow switch:Wide
antenna connector
Connect an audio genera-
through sn attenuator
tor to the [MIC]jack and
set as:
1kHz/100mV
Set an FM deviation
meter as:
HPF :OFF
LPF :20kHz
De-emphasis :OFF
Detector :(P-P)/2
Transmitting
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITIONS
MEASUREMENT
VALUE