Страница 1: ...OPERATING GUIDE OPERATING GUIDE FOR IC F3162DT DS IC F4160DT DS BIIS 1200 dPMR OPERATION...

Страница 2: ...is guide con tains important oper ating instructions for IC F3162DT DS vhf dpmr mobile transceiver IC F4162DT DS uhf dpmr mobile transceiver NOTE In this operating guide the LCD illustration is shown...

Страница 3: ...3 BIIS display 3 Receiving a call 3 Transmitting a call 7 Position data transmission 11 Stun function 11 BIIS ANI 11 Printer connection 12 3 dPMR OPERATION 13 27 dPMR operation 13 dPMR display 13 Rece...

Страница 4: ...d to toggle between the memory channel mode and the queue channel mode While in the queue channel mode push to toggle between the queue channel mode and the received message mode D For only dPMR opera...

Страница 5: ...status messages and SDM are selectable in the same mode D Additional key functions For both BIIS 1200 and dPMR operations The following key functions are recommended for BIIS 1200 and dPMR operations...

Страница 6: ...all is re ceived WAIT While transmitting CLR DOWN When a connection is terminated BUSY When the operating channel is busy Receiving a call D Receiving an Individual call q When an Individual call is r...

Страница 7: ...communication is finished push Moni Audi to send a Clear down signal to terminate the connection Either station can send a Clear down signal disappears CLR DOWN appears for approximately 2 sec onds a...

Страница 8: ...s alternately displayed In that case push Status Down to display the status message manually D Receiving an SDM q When an SDM is received Rings sound The calling station s ID or name and the SDM blink...

Страница 9: ...ll using the selected ID D Displaying a received message The transceiver memorizes up to six received messages When the seventh message is received the oldest mes sage will be removed and the last rec...

Страница 10: ...one Ask your dealer for details D Transmitting an Individual or Group call NOTE If you want to make a call to the pre programmed ID skip step q and w then directly go to step e q Push BIIS Button to...

Страница 11: ...annel is always used to send status mes sages q Push BIIS Button to enter the call code memory mode appears The pre programmed ID is displayed w Push CH Up or CH Down to select a desired Individual ID...

Страница 12: ...rn to the stand by mode D Direct message input Only 10 key version While displaying an SDM you can edit or change the mes sage q Push BIIS Button twice to enter the message selection mode then push CH...

Страница 13: ...ends the transceiver automatically starts an Emergency call cycle once or repeatedly de pending on the pre programmed repeat cycle setting e In an Emergency call cycle the transceiver automatically tr...

Страница 14: ...anDown item to Enable By the Automatic Position Data Transmission function When the function is activated the transceiver auto matically transmits position data according to the Time Marker and Interv...

Страница 15: ...r connection When a printer is connected to the transceiver through the OPC 966 interface cable received SDM and the calling station s ID can be printed out depending on the pre pro grammed settings A...

Страница 16: ...hen a connection is terminated ID When no name is programmed appears to the left of the calling station s ID TG When no name is programmed appears to the left of the Talkgroup ID Receiving a call D Re...

Страница 17: ...k at the same time eRelease PTT to receive r After the communication is finished push Clear to send a Disconnect signal to terminate the connection Either station can send a Disconnect signal disappea...

Страница 18: ...the call will be ignored and the transceiver will not be stunned killed or revived When a Stun command is received the transceiver is disa bled 1 In that case receiving a Revive command or input ting...

Страница 19: ...digital signal the Talk Back function is activated for Voice and Emergency calls and depending on the pre programmed settings also for status messages and SDM When the channel type is Mixed Digital Af...

Страница 20: ...ect CALL LOG e Push dPMR Button again to display a call log entry r Push CH Up or CH Down to display a desired entry If a Status or SDM call log entry is selected not only the calling station s ID but...

Страница 21: ...to store the setting The transceiver returns to the stand by mode NOTE Changing the channel or turning OFF the trans ceiver discards the new ID and returns the original one When no acknowledgement is...

Страница 22: ...ar to send a Disconnect signal to terminate the connection Either station can send a Disconnect signal D Transmitting a Status Polling Call The transceiver can send a signal that causes the target sta...

Страница 23: ...MR Button again to enter the application selec tion mode STATUS is displayed r Push dPMR Button again to enter the status message selection mode The pre programmed status message is displayed t Push C...

Страница 24: ...tion mode STATUS is displayed r Push CH Up or CH Down to select MESSAGE t Push dPMR Button again to enter the SDM selection mode The pre programmed SDM is displayed y Push CH Up or CH Down to select a...

Страница 25: ...characters u Push to move the cursor to the right push M to move the cursor to the left i Repeat steps y and u to enter a message of up to 100 characters o Hold down dPMR Button for 1 second to write...

Страница 26: ...nce or repeatedly de pending on the pre programmed repeat cycle setting e In an Emergency call cycle the transceiver automatically transmits a digital signal to inform the dispatcher that the user is...

Страница 27: ...IT is displayed while transmitting OK is displayed when an acknowledgement is received then the called station s microphone audio can be heard for the pre programmed time period FAILED is displayed wh...

Страница 28: ...wledgment is received y After a specified time period the transceiver will return to the stand by mode D Transmitting a Revive Call A Revive call allows you to send a command that will revive the stun...

Страница 29: ...et the Send with Emergency item to Enable After sending an Emergency call with the Man Down function Set the Send at ManDown item to Enable By the Automatic Position Transmission function When the fun...

Страница 30: ...inter is connected to the transceiver through the OPC 966 interface cable received SDM and the calling station s ID can be printed out depending on the pre pro grammed settings Ask your dealer or syst...

Страница 31: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...