5 - 2
¤
CONNECTION
FM
deviation meter
Speaker (8
Ω
)
to the antenna connector
Attenuator
30 dB
RF power meter
0.1– 6 W/50
Ω
Frequency
counter
Standard signal generator
–20 to 90 dBµ
(–127 to –17 dBm)
NEVER
transmit while
an SSG is connected to
the antenna connector.
To [SP]
To [MIC]
JIG cables
To [SP] connector
PC
to USB port
to USB port
to RS-232C port
OPC-478
(RS-232C type)
OPC-478U
(USB type)
OPC-478UC
(USB type)