2 Registering the radio (continued)
■
Site ID TX cycle (UC-FR5000)
Default Value: 5 seconds
Selectable range: 3 to 10 seconds
Set the time interval to transmit the
[Site ID] from the [Collect repeater]
and the [Home repeater] of a
Multi-site Trunked mode site.
Use the default value under normal
operation. If you adjust this value,
be sure it is longer than the radio’s
“Roaming Wait Timer”.
■
Ack RX Wait (CS-F3160/F5060)
Default Value: 0.8 seconds
Value range: 0.001 to 60.000 seconds
Set the time period for the radio to wait for an
acknowledgment from a repeater station, after
sending a [Call request].
If no acknowledgment is received within this set
time period, the radio repeats the call up to the
number of times, set in “Attempt No”.
■
Opening Text (CS-F3160/F5060)
Default Value: (No text)
Value range: Maximum 12 or 24 characters
TIPS: When turning ON the power, your programmed text is
displayed for 2 seconds, before starting the registration
procedure. Set this item to “No text” if you want the radio
to start the registration faster.