5 - 1
SECTION 5. ADJUSTMENT
PROCEDURE
¤
JIG CABLE
5-1 PREPARATION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Cloning software
CS-F3000 CLONING SOFTWARE
(Revision 1.0 or later)
JIG cable
Modifi ed OPC-478/U/UC
(See the illust below)
RF power meter
(50
Ω
terminated)
Measuring range
: 0.1–10 W
Frequency range
: 100–300 MHz
SWR
: Less than 1.2 : 1
Frequency counter
Frequency range
: 0.1–300 MHz
Frequency accuracy : ±1 ppm or better
Input level
: Less than 1 mW
Modulation
Analyzer
Frequency range
: 30–300 MHz
Measuring range
: 0 to ±10 kHz
Standard signal
generator (SSG)
Frequency range
: 0.1–300 MHz
Output level
: –20 to 90 dBµ
(–127 to –17 dBm)
AC millivoltmeter
Measuring range
: 10 mV to 10 V
Oscilloscope
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
Attenuator
Power attenuation
: 30 dB
Capacity
: More than 10 W
Audio generator
(AG)
Frequency range
: 300–3000 Hz
Output level
: 1–500 mV
External speaker
Input impedance
: 8
Ω
Capacity
: More than 1 W
¤
REQUIRED EQUIPMENTS
3-conductor 2.5 (d) mm plug
(MIC)
(GND)
33 k
3-conductor 3.5(d) mm plug
(CLONE)
OPC-478/U/UC
(GND)
(SP)
[JIG cable1]
[JIG cable2]
+ −
AC
MILLIVOLTMETER
(10 mV to 10 V)
AUDIO GENERATOR
(300–3000 Hz/1–500 mV)
+ −
PTT
+
4.7 µF
EXT. SPEAKER
(1 W/8
Ω)
+
−
SETTING;
Frequency : 1 kHz
Level
: 150 mV
Waveform : Sine wave
All manuals and user guides at all-guides.com