![Icom IC-F24 Скачать руководство пользователя страница 17](http://html2.mh-extra.com/html/icom/ic-f24/ic-f24_service-manual_4214897017.webp)
5 - 5
5-3 SOFTWARE ADJUSTMENTS (TRANSMITTING)
Select the operation using [
↑
] / [
↓
] keys, then set specified value using [
←
] / [
→
] keys on the connected computer keyboard.
Set to square wave
form
*For F24S/F25S adjustment.
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
PLL LOCK
VOLTAGE
[LV (RX LVA)]
[LV (TX LVA)
1
• Operating CH
: CH2 (*CH1)
• Receiving
PC
screen
" L V I N " i t e m o n t h e
CS-F14 ADJ's screen.
1.0 V
2
• Operating CH
: CH2 (*CH1)
• Connect an RF power meter or 50
Ω
dummy load to the antenna connector.
• Transmitting
1.0 V
CONVENIENT:
PLL LOCK VOLTAGE can be adjusted automatically.
Select "TX LVA"/"TX LVA" item on the CS-F14 ADJ screen, and push [ENTER] key.
3
• Operating CH
: CH5 (*CH2)
• Receiving
PC
screen
" L V I N " i t e m o n t h e
CS-F14 ADJ's screen.
3.3–4.5 V
(Verify)
4
• Operating CH
: CH5 (*CH2)
• Connect an RF power meter or 50
Ω
dummy load to the antenna connector.
• Transmitting
3.3–4.5 V
(Verify)
REFERENCE
FREQUENCY
[REF]
1
• Operating CH
: CH5 (*CH1)
• Transmitting
Top
panel
Loosely couple the frequency
counter to the antenna
connector.
470.0000 MHz
[US2], [EU2], [GE2]
520.0000 MHz
[US3], [GE3]
OUTPUT
POWER
[Power (Hi)]
1
• Operating CH
: CH1 (*CH1)
• Transmitting
Top
panel
Connect the RF power meter
to the antenna connector.
4.0 W
[Power (L2)]
2
• Operating CH
: CH3 (*CH2)
• Transmitting
2.0 W
[Power (L1)]
• Operating CH
: CH2 (*CH3)
• Transmitting
1.0 W
FM
DEVIATION
[MOD N]
(Narrow)
1
• Operating CH
: CH8 (*CH1)
• Set the deviation meter as:
HPF
:
OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (P_P)/2
• Connect the audio generator the [MIC]
connector and set as
: 1.0 kHz 150mV rms
• Transmitting
Top
panel
Connect the FM deviation
m e t e r t o t h e a n t e n n a
c o n n e c t o r t h r o u g h t h e
attenuator.
±2.10 kHz
[MOD Ratio]
(Middle; EUR only)
2
• Operating CH
: CH9 (*CH2)
• Transmitting
±3.20 kHz
[MOD Ratio]
(Wide)
3
• Operating CH
: CH9 (*CH2)
• Transmitting
±4.10 kHz
MODULATION
BALANCE
[BAL N]
(Narrow)
1
• Operating CH
: CH6 (*CH1)
• No audio applied to the [MIC] input.
• Set the deviation meter as:
HPF
:
OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (P_P)/2
• Transmitting
Top
panel
Connect the FM deviation
meter with the oscilloscope
to the antenna connector
through an attenuator.
[BAL Ratio]
(Middle; EUR only)
2
• Operating CH
: CH7 (*CH2)
• Transmitting
[BAL Ratio]
(Wide)
3
• Operating CH
: CH7 (*CH2)
• Transmitting