![Icom IC-E92D Скачать руководство пользователя страница 33](http://html2.mh-extra.com/html/icom/ic-e92d/ic-e92d_service-manual_4165815033.webp)
5 - 17
RECEIVE ADJUSTMENT (continued)
1) Select an adjustment item using [2]
/ [8] keys.
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] key to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
[145.1 MHz (S0 level)]
6
• Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency :
"(6)"
Level
: –8 dBµ
[
5#
]
Automatic
adjustment
(Push the
[BAND]
key)
[145.1 MHz (S3 level)]
• Set the SSG as;
Level
: –6 dBµ
[145.1 MHz (Full scale)]
• Set the SSG as;
Level
: 0 dBµ
[220.1 MHz (S0 level)]
7
• Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency
: 220.1 MHz
Level
: –8 dBµ
[220.1 MHz (S3 level)]
• Set the SSG as;
Level
: –6 dBµ
[220.1 MHz (Full scale)]
• Set the SSG as;
Level
: 0 dBµ
[305.2 MHz (S0 level)]
8
• Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency
: 305.2 MHz
Level
: –8 dBµ
[305.2 MHz (S3 level)]
• Set the SSG as;
Level
: –6 dBµ
[305.2 MHz (Full scale)]
• Set the SSG as;
Level
: 0 dBµ
[435.1 MHz (S0 level)]
9
• Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency :
"(7)"
Level
: –8 dBµ
[435.1 MHz (S3 level)]
• Set the SSG as;
Level
: –6 dBµ
[435.1 MHz (Full scale)]
• Set the SSG as;
Level
: 0 dBµ
[535.1 MHz (S0 level)]
10 • Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency
: 535.1 MHz
Level
: –8 dBµ
[535.1 MHz (S3 level)]
• Set the SSG as;
Level
: –6 dBµ
[535.1 MHz (Full scale)]
• Set the SSG as;
Level
: 0 dBµ
[800.1 MHz (S0 level)]
11 • Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency
: 800.1 MHz
Level
: –2 dBµ
[800.1 MHz (S3 level)]
• Set the SSG as;
Level
: 0 dBµ
[800.1 MHz (Full scale)]
• Set the SSG as;
Level
: 8 dBµ
[87.5 MHz (S0 level)]
12 • Displayed freq. : "
"
• Receiving
• Set the SSG as;
Frequency :
87.5MHz
Level
: 2 dBµ
Modulation
: 1 kHz
Deviation
: 52.5 kHz
[
59(
]
Push the
[BAND] key.
(Automatic
adjustment)
[87.5 MHz (S3 level)]
• Set the SSG as;
Level
: 5 dBµ
[87.5 MHz (Full scale)]
• Set the SSG as;
Level
: 12 dBµ