5 - 10
ADJUSTMENT MODE ADJUSTMENTS (Continued)
• The following adjustment must be performed at “ADJUSTMENT MODE”.
CTCSS
DEVIATION
(50 MHz)
(145 MHz)
(440 MHz)
DTCS
DEVIATION
(50 MHz)
(145 MHz)
(440 MHz)
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1
2
3
1
2
3
• Displayed frequency :
(CT ch.)
53.900 MHz
• No audio applied to the [MIC]
jack.
• Set an FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (p-p)/2
• Output power
: High
• Transmitting
• Displayed frequency :
(CT ch.)
145.000 MHz
• Transmitting
• Displayed frequency :
(CT ch.)
445.500 MHz
• Transmitting
• Displayed frequency :
(DS ch.)
51.000 MHz
• No audio applied to the [MIC]
jack.
• Set an FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (p-p)/2
• Output power
: High
• Transmitting
• Displayed frequency :
(DS ch.)
145.000 MHz
• Transmitting
• Displayed frequency :
(DS ch.)
445.500 MHz
• Transmitting
Top
Panel
Top
panel
Connect an FM
deviation meter to
the [ANT] connector
through an attenua-
tor.
Connect an FM
deviation meter to
the [ANT] connector
through an attenua-
tor.
± 0.55 kHz
± 0.55 kHz
± 0.65 kHz
± 0.5 kHz
± 0.6 kHz
± 0.6 kHz
Top
panel
Top
panel
[DIAL]
[DIAL]
[DIAL]
[DIAL]
[DIAL]
[DIAL]