14-3
D
D
Command table
14
CONTROL COMMAND
Command
Sub command
Description
00
—
Send frequency data
01
Same as
Send mode data
command 06
02
—
Read band edge frequencies
03
—
Read operating frequency
04
—
Read operating mode
05
—
Set operating frequency
06
00
Select LSB
01
Select USB
02
Select AM
03
Select CW
04
Select RTTY
05
Select FM
07
Select CW-R
08
Select RTTY-R
12
Select PSK
13
Select PSK-R
07
—
Select VFO mode
B0
Exchange main and sub bands
B1
Equalize main and sub bands
C0
Turn the dualwatch OFF
C1
Turn the dualwatch ON
D0
Select main band
D1
Select sub band
08
—
Select memory mode
0001–0101*
Select memory channel
*P1=0100, P2=0101
09
—
Memory write
0A
—
Memory to VFO
0B
—
Memory clear
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
∂
F scan start
12
Fine programmed scan start
13
Fine
∂
F scan start
22
Memory scan start
23
Select memory scan start
A1–A7
Set
∂
F scan span (A1=±5 kHz;
A2=±10 kHz; A3=±20 kHz;
A4=±50 kHz; A5=±100 kHz;
A6=±500 kHz; A7=±1 MHz)
B0
Set as non-select channel
B1
Set as select channel (1=
★
1;
2=
★
2; 3=
★
3; when no data com-
mand is specified, the previously
set number or “
★
1” is selected)
B2
Set the number for select memory
scan (0=ALL; 1=
★
1; 2=
★
2; 3=
★
3)
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the split function OFF
01
Turn the split function ON
10
00
Select 10 Hz (1 Hz) tuning step
01
Select 100 Hz tuning step
02
Select 1 kHz tuning step
03
Select 5 kHz tuning step
04
Select 9 kHz tuning step
05
Select 10 kHz tuning step
06
Select 12.5 kHz tuning step
07
Select 20 kHz tuning step
08
Select 25 kHz tuning step
Command
Sub command
Description
11
—
Select/read attenuator (0=OFF;
1=3 dB; 2=6 dB; 3=9 dB; 4=12 dB;
5=15 dB; 6=18 dB; 7=21 dB)
12
00 + RX ANT
Select/read ANT1 selection
(00=RX ANT OFF; 01=RX ANT ON)
01 + RX ANT
Select/read ANT2 selection
(00=RX ANT OFF; 01=RX ANT ON)
02 + RX ANT
Select/read ANT3 selection
(00=RX ANT OFF; 01=RX ANT ON)
03 + RX ANT
Select/read ANT4 selection
(00=RX ANT OFF; 01=RX ANT ON)
13
00
Announce with voice synthesizer
01
(00=all data; 01=frequency and
02
S-meter level; 02=receive mode)
14
01 + Level data
[AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data
[RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data
[SQL] level setting (0=11 o’clock to
255=max. CW)
05 + Level data
[APF] level setting
(0=Pitch–550 Hz, 128=Pitch,
255=Pitch+550 Hz; 10 Hz steps)
06 + Level data
[NR] level setting (0=min. to
255=max.)
07 + Level data
Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data
Outside [TWIN PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data
[CW PITCH] setting (0=300 Hz,
128=600 Hz, 255=900 Hz; 5 Hz
steps)
0A + Level data
[RF POWER] setting (0=max.
CCW to 255=max. CW)
0B + Level data [MIC] setting (0=max. CCW to
255=max. CW)
0C + Level data [KEY SPEED] setting (0=max.
CCW to 255=max. CW)
0D + Level data [NOTCH] setting (0=low freq. to
255=high freq.)
0E + Level data [COMP] setting (0=max. CCW to
255=max. CW)
0F + Level data
[DELAY] setting (0=max. CCW to
255=max. CW)
11 + Level data
[AGC] control setting (0=max.
CCW to 255=max. CW)
12 + Level data
[NB] control setting (0=max. CCW
to 255=max. CW)
13 + Level data
[DIGI-SEL] setting (0=max. CCW
to 255=max. CW)
14 + Level data
[DRIVE] setting (0=max. CCW to
255=max. CW)
15 + Level data
[MONI GAIN] setting (0=max.
CCW to 255=max. CW)
16 + Level data
[VOX GAIN] setting (0=max.
CCW to 255=max. CW)
17 + Level data
[ANTI VOX] setting (0=max. CCW
to 255=max. CW)
18 + Level data
[CONTRAST] setting (0=max.
CCW to 255=max. CW)
19 + Level data
[BRIGHT] setting (0=max. CCW
to 255=max. CW)