2-conductor 3.5 (d) mm (
1
⁄
8
″
) plug
to [REMOTE] jack
Rear panel
Front panel
JIG plug
Shorten the both terminals
[P.AMP/ATT]
[TUNER/CALL]
[PWR]
KEY
ACC
DATA
MIC
ANT2
ANT1
DC 13.8V
GND
4 - 1
SECTION 4
ADJUSTMENT PROCEDURES
4-1 PREPARATION
Some adjustment must be performed on the adjustment mode.
M
REQUIRED TEST EQUIPMENT
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RENGE
DC power supply
Output voltage
: 13.8 V DC
Current capacity
: 30 A or more
Distortion meter
Frequency range
: 1 kHz ±10 %
Measuring range
: 1–100 %
RF power meter
(treminated type)
Measuring range
: 0.5–200 W
Frequency range
: 1.8–500 MHz
Impedance
: 50
Ω
SWR
: 1.2 : 1 or better
Oscilloscope
Frequency range
: DC–100 MHz
Measuring range
: 0.01–10 V
Digital multimeter
Imput impeadance : 10 M
Ω
/DC or more
AC millivoltmeter
Measuring range
: 10 mV to 10 V
Frequency counter
Frequency range
: 0.1–500 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity
: 100 mV or better
DC voltmeter
Input impedance
: 50 k
Ω
/V DC or more
DC ammeter
Measuring capability : 5 A/30 A
RF voltmeter
Frequency range
: 0.1–500 MHz
Measuring range
: 0.01–10 V
Audio generator
Frequency range
: 300–3000 Hz
Measuring range
: 1–500 mV
Standard signal
generator (SSG)
Frequency range
: 0.1–500 MHz
Output level
: 0.1 µV to 32 mV
(–127 to –17 dBm)
External speaker
Input impedance
: 8
Ω
Capacity
: 5 W or more
M
ENTERING THE ADJUSTMENT MODE
q
Turn the transceiver’s power OFF.
w
Connect the JIG plug (see illustration below) to [REMOTE] jack on the rear panel.
e
While pushing and holding [P.AMP/ATT] and [TUNE/CALL], turn the transceiver power ON.
NOTE:
Exiting from the adjustment mode when the transceiver's power is OFF.
M
OPERATING ON THE ADJUSTMENT MODE
• Enter DDS adjustment mode.
: Push [F-1 (REF)]
• Enter TX adjustment mode.
: Push [F-2 (TX)]
• Enter RX adjustment mode.
: Push [F-3 (RX)]
• Store the set value.
: Push [F-4 (SET)]
• Adjust the value.
: Rotate [DIAL]
CAUTION:
Connect a dummy load to the antenna con-
nectors during the transmitter adjustment,
when the adjustment condition does not re-
quire a test equipment.
[F-1(REF)]
[F-3 (RX)]
[DIAL]
[F-2 (TX)]
[F-4 (SET)]
Содержание IC-7000
Страница 1: ...SERVICE MANUAL HF VHF UHF ALL MODE TRANSCEIVER S 14214HZ C1 Dec 2005 ...
Страница 27: ...4 12 L703 L702 RX peak adjustment point MAIN UNIT ...
Страница 29: ...4 14 C1423 WFM distortion adjustment point MAIN UNIT ...
Страница 55: ......
Страница 92: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14214HZ C1 2005 Icom Inc ...