45
7
SCAN OPERATION
New2001
■
Scan resume condition
The scan resume condition can be selected as timer or pause
scan. The selected resume condition is also used for priority
watch. (p. 47)
q
Push [MAIN•BAND] to select the desired band (left or right)
as the main band.
w
Push [SET•
] to enter set mode.
e
Push [SET•
] or [LOW•PRIO] several times until “SCt”
or “SCP” appears as shown above.
• When “d” is displayed in place of the 100 MHz digit, cancel the
DTMF memory encoder in advance. (p. 50)
r
Rotate the main band’s [DIAL] to set the desired timer:
• “SCt-15”
: Scan pauses 15 sec. while receiving a signal.
• “SCt-10”
: Scan pauses 10 sec. while receiving a signal.
• “SCt-5”
: Scan pauses 5 sec. while receiving a signal.
• “SCP-2”
: Scan pauses until the signal disappears and then
resumes 2 sec. later.
t
Push [TONE•DTMF] to exit set mode.
z
Push [BAND] to select the desired band (left or
right) as the main band.
x
Push [
SET
B(D-OFF)] to enter set mode.
c
Push [
SET
B(D-OFF)] or [
ENT
C(T-OFF)] several
times until “SCt” or “SCP” appears as shown at
left.
v
Push [
Y
] or [
Z
] to select the scan resume condi-
tion.
• See item
r
at left for scan resume condition details.
b
Push [
CLR
A(MW)] to exit set mode.
SET
B
MAIN
T X
M
The display shows that the
scan will resume 15 sec. after
it stops.
USING
SET MODE
IC-2720H_2.qxd 03.5.13 9:45 Page 45 (1,1)