9
SOFTWARE ADJUSTMENT-Continued
TRACKING
(Middle2
band)
[Tr]
(High band)
[Tr]
S-METER
[SL]
9
10
11
12
13
14
15
1
2
3
4
• Operating frequency
: 400.1 MHz
• Connect an SSG to the antenna connector and set as
Level
: 1 µV* (–107 dBm)
Modulation
: 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
• Operating frequency
: 429.9 MHz
• Receiving
• Operating frequency
: 480.1 MHz
• Receiving
• Operating frequency
: 549.9 MHz
• Receiving
• Operating frequency
: 810.1 MHz
• Connect an SSG to the antenna connector and set as
Level
: 1 µV* (–107 dBm)
Modulation
: 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
• Operating frequency
: 905.1 MHz
• Receiving
• Operating frequency
: 999.9 MHz
• Receiving
• Operating frequency
: 146.1 MHz
• Connect an SSG to the antenna connector and set as
Level
: 1 µV* (–107 dBm)
Modulation
: 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
• Operating frequency
: 445.1 MHz
• Receiving
• Operating frequency
: 435.9 MHz
• Receiving
• Operating frequency
: 810.1 MHz
• Set an SSG as
Level
: 5.6 µV* (–92 dBm)
Modulation
: 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
• Push the [BAND] key.
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.