DL7MAJ, Oct 20
th
2015
Page 14 (21)
VFO
1)
Let the VFO warm up for app. 10 Minutes
2)
Adjust tuning range of VFO with L1 to exactly 1000kHz (use internal calibrator as
reference)
3)
If you adjust L1, a realignment of the mechanical scale is necessary.
4)
Repeat 3) and 3) if necessary
Be very careful! Use plastic trimmers only – otherwise destruction of L1 will result!
(And you are a fool for the rest of you life….)