background image

 LIGHTED POWER SWITCH [POWER]

  Toggles to turn the repeater AC power ON 
  or  OFF. Located on the back panel of the    
  repeater.
 

NOTE: 

Does not effect DC power input.

 

TRANSMIT ANTENNA CONNECTOR [TX/   

  TX•RX]

 ➥ 

Connects a transmit antenna (impedance:    

  50 

Ω

) and outputs transmit signals.

 ➥ 

When an optional internal duplexer is  

 

  installed, this connects the Transmit and
  Receive Radios to an antenna.

 ➥ 

N Female Connector.

➌ 

ACCESSORY CONNECTOR [ACC]

  Connects to the remote controller.
  • See pg. 3 for accessory connector    

 

  information.

 

 RECEIVE ANTENNA CONNECTOR [RX]

 ➥

Connects a receive antenna (impedance: 50  

 

Ω

) and inputs receiving signals.

 ➥

When an optional internal duplexer is   

  installed, do not use this connector.

 

➥ 

N Female Connector.   

  

 AC POWER SOCKET [AC]

  Connects the supplied AC power cable to a   
  120V or 220V AC outlet.
  120V or 220V internal jumper selectable.

➏ 

GROUND TERMINAL [GND]

  Ground the repeater through this terminal    
  to prevent electric shocks, TVI, BCI and other  
  problems.

 DC POWER INPUT TERMINALS [BATTERY

]

  Connects the 12 V storage battery for  

 

  the repeater backup when the AC power is    
  interrupted. These terminals are also used for  
  DC power operation. Battery is automatically  
  recharged when AC power is restored.

 
  CAUTION: NEVER

 short the (+) line of the    

  DC power cable to repeater’s chassis, when   
  connecting DC power cable to the [BATTERY] 
  terminals. Otherwise, there is danger of  

 

  electric shock and/or equipment damage.

 LAN CONNECTOR

 for ethernet connection 

  when optional UC-FR5000 controller 
  installed.

 BUS CONNECTORS

 for data communication 

  among optional UC-FR5000 controllers.
 

■ 

Rear Panel

     

 

 

   PANEL DESCRIPTION    1 

 

            

2

Содержание CY 5000

Страница 1: ... INSTRUCTION MANUAL VHF FM REPEATER CY 5000 UHF FM REPEATER CY 6000 ...

Страница 2: ...rnal part or connectors on the rear panel of the repeater This may result in an electric shock NEVER expose the repeater to rain snow or any liquids AVOID using or placing the repeater in areas with temperatures below 30 C 22 F or above 60 C 140 F Be aware that temperatures on a vehicle s dashboard can exceed 80 C 176 F resulting in permanent damage to the repeater if left there for extended perio...

Страница 3: ...eration FEATURES Automatic battery backup and charging system A built in backup system supports automatic switching to an external battery 13 6 V DC if the AC power supply fails Other features PC programmable 19 inch rack mount or desktop SUPPLIED ACCESSORIES The following accessory is supplied with CY FR series AC120V version AC power cable OPC 510 1 ii ...

Страница 4: ... modular jack accepts the optional Field Service Aid 1 PANEL DESCRIPTION Front Panel 1 8 V DC output Max 15 mA Output port for PC programming AFO M PTT Input port for TX control Microphone ground Microphone input Ground Input port for PC programming ...

Страница 5: ... Connector AC POWER SOCKET AC Connects the supplied AC power cable to a 120V or 220V AC outlet 120V or 220V internal jumper selectable GROUND TERMINAL GND Ground the repeater through this terminal to prevent electric shocks TVI BCI and other problems DC POWER INPUT TERMINALS BATTERY Connects the 12 V storage battery for the repeater backup when the AC power is interrupted These terminals are also ...

Страница 6: ...p Active L 16 EXT I O 16 The desired function can be assigned Default P0 Monitor Output 5 V pull up Active L 17 EXT I O 17 The desired function can be assigned Default Busy Output 5 V pull up Active L 18 EXT I O 18 The desired function can be assigned Default Null 5 V pull up Active L 19 EXT I O 19 The desired function can be assigned Default EPTT Input 5 V pull up Active L 20 DATA IN Input termin...

Страница 7: ...th your local dealer for more information and recommendations Duplexer A duplexer is separately required when only one antenna is used for both transmitting and receiving Select a duplexer according to the transmitting and receiving frequencies Ask your Dealer for details Grounding To prevent electrical shock television interference TVI broadcast interference BCI and other problems ground the tran...

Страница 8: ...ith following current capacity Solder or clamp the cable plug when connecting the power cable to the backup battery to prevent voltage drops Power cable current capacity 25 A or more TX TX RX ANT RX ANT GROUND 5 NOTE Must have minimum 20 vertical separation when using separate antennas TX RX antenna required for installing an internal duplexer ...

Страница 9: ...could result in fire risk An International AC power cable is available The internal AC power supply is jumper selectable between 120Vac and 220Vac In DC operation CAUTION Voltages greater than 16 VDC will damage the repeater Check the source voltage before connecting the power cable DO NOT place the backup battery on or near the repeater Lead acid batteries should be placed at least 5 m 16 4 ft aw...

Страница 10: ...t is installed or adjust the internal units etc CAUTION Disconnect the AC power cable and or DC power cable from the repeater Otherwise there is danger of electric shock and or equipment damage Remove 3 screws from the top of the repeater and 4 screws from the sides then lift up the top cover 7 OPTIONAL PRESELECTOR OPTIONAL DUPLEXER ...

Страница 11: ...ted from the speaker Transmitting for Local Control Take the microphone off hook Wait for the channel to become clear Push and hold PTT to transmit then speak into the microphone at your normal voice level Release PTT to receive IMPORTANT To maximize the readability of the transmitted signal 1 Pause briefly after pushing PTT 2 Hold the microphone 1 to 2 inch 2 5 to 5 cm from your mouth then speak ...

Страница 12: ...r the repeater stops functioning try to find the source of the problem and replace the damaged fuse with a new rated fuse 9 CAUTION DISCONNECT the DC power cable from the repeater Otherwise there is a danger of electric shock and or equipment damage ...

Страница 13: ...85 250 VAC 50 60 hz 13 6 VDC nominal 16 2 Amp Max Dimensions Projections 480 W x 133 H x 364 D mm not included 18 90 W x 524 H x 14 33 D in Weight 8 6 kg 18 lb 10 Optional Duplexer and Preselector specifications not listed All specifications are subject to change without notice See UR Service Manual for module specifications ...

Страница 14: ...NE HM 152T DTMF MICROPHONE Hand microphone with a DTMF keypad SM 25 DESKTOP MICROPHONE SP 22 SPEAKER IAS VHF DUP KIT VHF duplexer kit with RF jumpers IAS UHF DUP KIT UHF duplexer kit with RF jumpers 220V AC Power Cord Preselectors VHF FIP PR 16 4H PE UHF FIP PR 46 4C PE ...

Страница 15: ...MEMO ...

Страница 16: ...2009 Icom America Inc The Icom logo is a registered trademark of Icom Inc All specifications and information is subject to change without notice or obligation All other trademarks remain the property of their respective owners ...

Отзывы: