ICM Controls SC3211L Скачать руководство пользователя страница 2

4

7

5

8

6

9

10

11

12

13

14

15

Wiring Diagrams

Single Compressor

Cool Active 

Heat Pump – with electric backup

Dual Compressor

Cool Active 

Heat Pump

Note:

 For systems without emergency strip heat, a jumper wire should be placed between W2 & E.

Transformer

120 

VAC

24 VAC

Reversing Valve

Compressor

Auxiliary Heat

Service Led Wire

Emergency Heat

Fan

Compressor #2

Transformer

120 

VAC

24 VAC

Reversing Valve

Compressor #1

Service Led Wire

Emergency Heat

Fan

NOTE:

 Place jumper between W2 and Y2

Single Compressor

Heat Active 

Heat Pump – with electric backup

Dual Compressor

Heat Active 

Heat Pump

Note:

 For systems without emergency strip heat, a jumper wire should be placed between W2 & E.

Transformer

120 

VAC

24 VAC

Reversing Valve

Compressor

Auxiliary Heat

Service Led Wire

Emergency Heat

Fan

Compressor #2

Transformer

120 

VAC

24 VAC

Reversing Valve

Compressor #1

Service Led Wire

Emergency Heat

Fan

NOTE:

 Place jumper between W2 and Y2

Operation

Setting the Setpoint Temperature

Parts Diagram

Reset switch

Configuration switch

Mode switch

Up button

Down button

Fan switch

Left (PROG) button

Right (HOLD) button

Field programming pins

The SimpleComfort

®

 

SC3211L

 thermostat has buttons that are used to:

• Adjust the setpoints of the thermostat 

• Set the operation mode 

• Program the schedule                      

• Enter vacation Hold 

• Reset the thermostat 

• Activate the program feature

1.  With the system switch in 

Heat, Emergency Heat

 or 

Cool

, the current temperature setpoint displays.

2.  Press the 

up

 or 

down

 button until the desired temperature setpoint displays.

3.  The new temperature setpoint is automatically saved in memory.

6. 

Lockout 

(0°F-8°F) (0°C-4°C)

 –

 Select the number of degrees set 

temperature can be changed during keypad lockout

 

Press the 

up

 or 

down

 button to select.

 

Press the 

right

 button to advance to the next screen.

7. 

Maximum Heat Setpoint

 (45°F to 90°F) (7°C to 32°C) 

 

Adjust to control the maximum heat set temperature allowed.

 

Press the 

up

 or 

down

 button to select.

 

Press the 

right

 button to advance to the next screen.

5.

  Auxiliary Delay ON

 – (0-30 minutes) – Set the delay time in minutes for auxiliary 

heat to be locked out after a call for second stage. This extra savings feature is 
used to temporarily lock out auxiliary heat devices, allowing just heat pump to try to 
satisfy heat call.

  Press the 

up

 or 

down

 button to select.

 

Press the 

right 

button to advance to the next screen.

4. 

Staged Off Outputs

  

  Select whether the outputs for heating and cooling are staged off independently or 

are satisfied simultaneously.

  1 = outputs staged off independently     
  0 = outputs off simultaneously
  Press the 

up

 or 

down

 button to set.

  Press the 

right 

button to advance to the next screen.

Configuration Mode Settings

The setup screens for Configuration Mode are as follows:

1. 

Temperature Scale (F or C) –

 Choose Fahrenheit or Celsius.

  Press the 

up

 or 

down

 button to select.

  Press the 

right

 button to advance to the next screen.

3. 

2

nd

 Stage Temperature Differential

 (1°F to 5°F) (1°C to 3°C) 

  Set the number of degrees between when stage 1 turns on and when stage 2 turns 

on.

  Press the 

up

 or 

down

 button to set differential value.

  Press the 

right 

button to advance to the next screen.

2. 

1

st

 Stage Temperature Differential

 (1°F to 5°F) (1°C to 3°C)

Set the number of degrees between your “setpoint” temperature and your “turn on” 

temperature.

  Press the 

up

 or 

down

 button to set differential value.

  Press the 

right 

button to advance to the next screen.

Configuration Mode

1. 

Verify the 

SC3211L

 is in the 

OFF

 mode.

 

Slide the system switch until off mode displays.

2.  Remove the cover of the thermostat by gently pulling near one of the corners at 

the top of the thermostat.

3.  Press the 

CONFIG

 button for 1 second while the 

SC3211L

 is in 

OFF 

mode.

To exit confi

guration mode, press the 

CONFIG

 switch for 1 second or slide 

the mode switch to heat or cool.

Press the 

up

 or 

down

 button to change settings within each screen.

Down

 

button

Up 

button

Press the

 right

 button to advance to the next screen.

 

Note:

 Pressing the 

left

 button will return you to the previous screen.

Left 

button

Right 

button

The configuration mode is used to set the 

SC3211L

 to match your heat pump system. 

To configure the 

SC3211L

, perform the following steps:

8. 

Minimum Cool Setpoint

 (45°F to 90°F) (7°C to 32°C) 

 

Adjust to control the minimum cool set temperature allowed.

 

Press the 

up

 or 

down

 button to select.

 

Press the 

right

 button to advance to the next screen.

9. 

Room Temperature Offset

 (+9°F to -9°F) (+5°C to -4°C) 

 

Adjust to calibrate displayed room temperature to match actual room temperature. 

 

Press the 

up

 or 

down

 button to select.

 

Press the 

right

 button to advance to the next screen.

10. 

Maximum Cycles Allowed Per Hour

 (- -, 2-6) 

 

  - - = as many as needed, 2-6 = maximum cycles/hour

 

Press the 

up

 or 

down

 button to select.

 

To exit configuration mode, press 

the 

configuration

 button for 2 seconds or slide the 

mode switch to heat or cool.

Starting the Thermostat

CAUTION!

Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage 

your air conditioning system and cause personal injuries.

1.  Move the 

Fan Auto/On

 switch to the 

Auto

 position.

2.  Move the 

Cool/Off/Heat

 switch to 

Cool

 or 

Heat

, depending on the season.

Room Temperature

OFF Indicator

Time

Testing the Thermostat

Once the thermostat is installed, it should be thoroughly tested.

CAUTION!

Do not energize the air conditioning system when the outdoor temperature is below 50 degrees. It 

can result in equipment damage or personal injury.

Cool Test

1.  Slide system switch to Cool position. Cool mode screen is displayed. 
2.  Adjust set temperature so it is 5 degrees below room temperature.
3.  Air conditioning should come on within a few seconds.
4.  Adjust the set temperature 2 degrees above the room temperature and the A/C should 

turn off. There may be a fan delay on your system.

 

 Note:

 There is a four minute delay to protect your compressor.

Heat Test

1.  Slide system switch to Heat position. Heat mode screen is displayed.
2.  Adjust the set temperature so it is 5 degrees above the room temperature.
3.  Heat should come on within a few seconds.
4.  Adjust the set temperature so it is 2 degrees below the room temperature and the 

heat should turn off. There may be a fan delay on your system.

 

 Note:

 There is a four minute delay to protect your compressor.

Fan Test

1.  Slide Fan switch to 

On

 position.

2.  Indoor fan turns 

ON

3.  Slide Fan switch to 

Auto

 position.

4.  Indoor fan turns 

OFF

.

Operating Modes

OFF Mode

• In this mode, the thermostat will not turn on the heating or cooling devices (manual fan can operate) 
• 

OFF

 mode is also used to access setup and the program schedule

Cool Mode

• In this mode, the thermostat controls the cooling system
• Press the 

PROG

 button to enter and exit 

Program Cool

 mode

• In 

Program Cool

 

(PROG solid on display)

 mode, the thermostat will follow the program schedule that is stored in 

memory

Heat Mode

• In this mode, the thermostat controls the heating system
• Press the 

PROG

 button to enter or exit the 

Program Heat

 mode 

• In 

Program Heat

 

(PROG solid on display)

 mode, the thermostat will follow the program schedule that is stored in 

memory 

Emergency Heat Mode

• In this mode, the thermostat controls the heating system and the heat pump is disabled
• Press the 

PROG

 button to enter or exit the 

Program Emergency Heat

 mode 

• In 

Program Emergency Heat

 

(PROG solid on display)

 mode, the thermostat will follow the program schedule that 

is stored in memory

Hold Functions

When in 

Programmable Cool

Programmable Heat or Programmable Emergency Heat

, you can lock in the 

present settings indefinitely by pressing the 

Hold

 button once (PROG flashes). Press 

Hold 

button again to exit 

Hold

 

mode (PROG solid). For a temporary hold period, raise or lower set temperature to desired set temperature. The 
thermostat will automatically return to programmed set temperature after 2 hours.

Setting the Time and Day of the Week

2.  Press and hold the 

PROG

 button (left) and 

HOLD

 (right) buttons (simultaneously) in for 6 seconds.

1.  Slide the system switch to the OFF position. You are in the OFF mode.

The time and day of the week must be set for your program schedule to operate correctly.

5.  Press the

 HOLD 

(right) button once to select day of the week (TODAY flashing).

  Press the up or down button to select current day of the week
  (01/Monday, 02/Tuesday, etc.).
 

 

Note:

 At any time, press the

 PROG 

(left) button to return to the previous screen or 

press the

 HOLD 

(right) button to advance to the next screen.

Press the 

PROG

 button and 

HOLD

 button (simultaneously) in for 2 seconds to lock 

values into memory and return to the OFF mode or press the

 HOLD 

(right) button once 

to enter programming.  

4.  Press the

 HOLD 

(right) button once to select minutes (minutes flashing).

  Press the up or down button to adjust the minutes.

3. 

Time displays (hour flashing).

  Press the up or down button to adjust the hour.

Setting the program schedule:
1.  Slide the

 

system switch to the center position. You are in 

OFF

 mode.

2.  Press and hold the 

PROG

 and

 HOLD 

buttons (pressed simultaneously) for 6 seconds.

3.  Press the

 HOLD 

(right) button 3 times.

4.  Day 1-7 are blinking.

From this screen you have 2 options: 
1.  Press the

 HOLD 

(right) button to begin programming all 7 days at one time, or

2.  Press the up button to see the other programming options.

  

Note:

 The days of the week shown on the display will be programmed simultaneously. 

 

The screens are listed below.

Screen 1

1-7

SUN

MON

TUE

WED

THU

FRI

SAT

Screen 2

1-5

MON

TUE

WED

THU

FRI

Screen 3

01

MON

Screen 4

02

TUE

Screen 5

03

WED

Screen 6

04

THU

Screen 7

05

FRI

Screen 8

6-7

SUN

SAT

Screen 9

06

SAT

Screen 10

07

SUN

Program Overview

The 

SC3211L

 programmable thermostat has four periods (MORN, DAY, EVE, NITE) that are customizable for each 

day of the week. Each period will have a start time, heat temperature, and cool temperature. The 

SC3211L

 monitors 

the day and time, while maintaining the specific conditions you have chosen for each period in your program.

Отзывы: