background image

ONE-YEAR LIMITED WARRANTY

The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the 
date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for 
the purchase prices of the goods which are provided to be defective. The warranty and remedies set forth herein 
do not apply to any goods or parts thereof which have been subjected to misuse including any use or application 
in violation of the Seller’s instructions, neglect, tampering, improper storage, incorrect installation or servicing not 
performed by the Seller. In order to permit the Seller to properly administer the warranty, the Buyer shall: 1) Notify 
the Seller promptly of any claim, submitting date code information or any other pertinent data as requested by the 
Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed to be defective 
and are determined by Seller to be non-defective are subject to a $30.00 per hour inspection fee. This warranty 
constitutes the Seller’s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory. 
Unless otherwise stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for 
any particular purpose.

LIAF022

Patent No. - Design: 424,953

Patent No. - Thermal Intrusion Barrier: 6,597,275

Patent Pending - SimpleSet

TM

 Target Programming Technology

7313 William Barry Blvd., North Syracuse,  NY  13212

(

Toll Free) 800-365-5525     (Phone) 315-233-5266     (Fax) 315-233-5276

www.icmcontrols.com

Operating Modes

These are the possible operating modes of the 

SC2311L

.

Off Mode 

In off mode, the thermostat will not turn on the heating or cooling appliances.

    

Note 2:

 

The indoor fan can be activated in every mode by sliding the Auto/On fan to the On 
position.

    

Note 2:

 

Off mode in used to enter the configuration setup (by pressing 

LEFT

 and 

RIGHT

 

simultaneously for 5 seconds).

Cool Mode

In cool mode, the thermostat controls the cooling system. 
There is a four minute time delay after the compressor turns off. This protects the compressor.

Heat Mode

In heat mode, the thermostat controls the heating system.
For heat pumps, there is a four minute time delay after the compressor turns off. This protects the 
compressor.

Emergency Heat Mode

 (Heat pump systems only)

In emergency heat mode, the heat pump system will be disabled and auxiliary heat will become the 
primary source of heat.

 

ENTER

  Emergency heat mode by pressing the up button for ten seconds while in heat mode. “EH” 

will then display on the screen.

 

EXIT

  Emergency heat mode by pressing the up button for ten seconds. “EH” will not display on 

the screen when you exit emergency heat mode.

The 

SC2311L

 also exits emergency heat mode when the mode switch is moved to Cool.

This feature is used for transferring the configuration settings from the master to the target 
thermostat. All thermostats for a job can be mounted and powered up. Configure one thermostat. This 
will be the master. The master will be used to copy the configuration to the rest of the thermostats.

Preparing the master to Send:

1. The master must be powered by 24 VAC.
2. Verify the master thermostat is in 

OFF

 mode. Slide system switch to center 

position.

3. Remove cover of the master thermostat by gently pulling near one of the corners 

at the top of the thermostat.

4. Press the 

up

 and 

down

 buttons and 

LEFT

 switch simultaneously for 5 seconds.

5. The 

OUT

 screen displays indicating the master thermostat is ready to 

transfer data.

 

 

Note:

 

Press the 

up

 and 

down

 buttons and 

LEFT

 switch simultaneously for 5 

seconds to exit from data transfer mode and to return the master to the 

OFF

 mode.

6. Connect the master to the target using the 3 wire connector. Attach one end to 

the Master’s FP pins and the other end to the Target’s FP pins.

 

 

Note:

 

Target thermostat must be powered by 24 VAC for field programming 
to occur.

When the connection has been made correctly, the master thermostat will power 
up and the target will count from 6 down to 1. It will then display 

LOC

 confirming 

the data has been saved in memory.
When all target thermostats have been completed, reinstall the master thermostat.
Press the 

up

 and 

down

 buttons and the 

LEFT

 switch simultaneously for 5 seconds to exit 

from the data transfer mode and to return the master thermostat to the 

OFF

 mode.

SimpleSet

TM

 Field Programming

FP Pins

SC2010 N/L

Lockout Feature

The 

SC2311L

 has a button lockout feature so the temperature adjustment is prohibited 

or limited. Select the appropriate lockout from Configuration Mode Settings (Step 7) of 
this guide.
To activate the LOC feature:
1. Simultaneously press the 

LEFT, RIGHT 

and 

UP

 buttons for 10 seconds.

2. LOC will display and the lockout function will be enabled.
To deactivate the LOC feature, repeat steps 1 and 2 above.

Troubleshooting

Symptom

Remedy

No display

Check for 24 VAC at thermostat; display is blank when 24 VAC is not 
present

System fan does not come on 
properly

Verify wiring is correct, check heat source configuration settings

 

(see Configuration Mode Setting 5)

All thermostat buttons are 
inoperative

Verify 24 VAC is present; unit locks out when 24 VAC is not present

No response with first button press

First button press activates backlight only

Thermostat turns on and off too 
frequently

Adjust temperature differential (see Configuration Mode Setting 2)

Fan runs continuously

Slide FAN switch to auto to turn fan off

Room temperature is not correct

Calibrate thermostat (see Configuration Mode Setting 10) 

LOC displays when any button is 
pressed

Thermostat has the button lockout function activated 

 

(see Lockout Feature, and Configuration Mode Setting 7)

Heat or Cool not coming on

Verify wiring is correct, verify configuration settings are correct

Problem not listed above

Press Reset button once*

* Reset Button Function

: Configuration settings are unchanged and display is refreshed.

Starting the Thermostat

Room Temperature

CAUTION!

Do not use air conditioning when the outdoor temperature is below 50 degrees. 
This can damage your air conditioning system and cause personal injuries.

1. Move the 

Fan Auto/On

 switch to the 

Auto

 position.

2. Move the 

Cool/Off/Heat

 switch to 

Cool

 or 

Heat

, depending on the season.

Mode of Operation

The 

SC2311L

 is a two-stage heat, one-stage cool thermostat. It functions with air conditioning, heat 

pumps, gas, oil or electric heat. 

The thermostat activates the first stage heat when the room temperature is below the heat set 
temperature (by the differential temperature). Second stage heat will be activated if the room 
temperature continues to drop. The heat outputs are staged off as the room temperature increases. 
For heat pump systems, the thermostat will not let the compressor come on for four minutes after it 
turns off. This protects your compressor. 

When the room temperature is greater than the cool set temperature (by the differential temperature), 
the cooling device is activated. The cool output is turned off as the room temperature drops. The 
thermostat will not let the compressor come on for four minutes after it turns off. This protects your 
compressor.

The 

SC2311L

 has the following operating modes: OFF, Heat, Emergency Heat, and Cool. In OFF 

mode, the thermostat will not turn on heating or cooling devices. In the Heat mode, the thermostat 
controls the heating system. For heat pump systems, Emergency Heat mode is used to bypass 
the compressor (only backup heat operates). In the Cool mode, the thermostat controls the cooling 
system. The indoor fan can be turned on in all operating modes using the Fan switch.  

Fan Test

1.  Slide 

Fan

 switch to 

On

 position. 

2.  Indoor fan turns on.

Auto

      

On

Auto

      

On

3.  Slide 

Fan

 switch to 

Auto

 position.   

4.  Indoor fan turns off.

Once the thermostat is installed, it should be thoroughly tested.  

CAUTION!

Do not energize the air conditioning system when the outdoor temperature is 

below 50 degrees. It can result in equipment damage or personal injury.

Testing the Thermostat

Cool Test

1.  Slide 

Mode

 switch to 

Cool

 mode.  

2.  Adjust set temperature so it is 5 degrees below room temperature. 
3.  Air conditioning should come on within a few seconds.
4.  Adjust the set temperature 2 degrees above the room temperature and the A/C should turn off.  

There may be a fan delay on your system.

 

 

Note:

 

There is a four minute time delay to protect the compressor after it turns off. To 

temporarily bypass the four minute delay, slide the 

Mode

 switch to 

OFF

 for 2 seconds 

and then back to 

Cool

.

Cool  Off  Heat

Heat Test

1.  Slide 

Mode

 switch to 

Heat

 mode. 

2.  Adjust the set temperature so it is 5 degrees above the room 

temperature.

3.  Heat should come on within a few seconds.   
4.  Adjust the set temperature so it is 2 degrees below the room 

 

temperature and the heat should turn off.  There may be a fan delay on your system.

 

 

Note:

 

There is a four minute time delay to protect the compressor after it turns off. To 

temporarily bypass the four minute delay, slide the 

Mode

 switch to 

OFF

 for 2 seconds 

and then back to 

Heat

.

Cool  Off  Heat