Setting the Temperature Differential

The default temperature differential is 1°. When your room temperature varies by 1°F, the thermostat 
turns on your system. If you notice your system turning on and off too frequently, increase the 
temperature differential. 
1.  Reset the thermostat by removing batteries for 10 seconds and then reinstall them.
2.  For the first 10 seconds of operation, the temperature differential is displayed. 
3.  Press the 

down

 or 

up

 button to select desired setting.

Starting the Thermostat

1.  Move the 

Off/Heat

 switch into the 

Heat

 position.

A Quick Test

Do not short jumper across terminals on the gas valve or at the system control to test installation. 

Action:

 Set the 

Off/Heat

 switch to 

Heat

; press the 

up

 button until the set temperature is 3°F above 

the room temperature. 

 

Result:

 The heating system should turn on; there may be a time delay depending on your 

system.

Action:

 Press the 

down

 button until the set temperature is below the room temperature.

 

Result:

 The heating system should turn off.

If the above 

test was successful

, you have a proper installation. 

If the above 

test was unsuccessful

, double check that the wires are securely connected and are 

connected to the proper terminals. Consult the troubleshooting section below.

Troubleshooting

Symptom

Remedy

The system is not turning on

Check batteries; display is blank when batteries are not 
present or are dead.

LCD is blank, or displaying 

LO BAT

Replace batteries, or make sure the existing ones are 
properly installed.

Thermostat turns on and off too 
frequently

Adjust temperature differential 

 

(see “Setting the Temperature Differential”).

ONE-YEAR LIMITED WARRANTY

The Seller warrants its products against defects in material or workmanship for a period of one (1) year 
from the date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a 
non-case credit for the purchase prices of the goods which are provided to be defective. The warranty and 
remedies set forth herein do not apply to any goods or parts thereof which have been subjected to misuse 
including any use or application in violation of the Seller’s instructions, neglect, tampering, improper storage, 
incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly 
administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code 
information or any other pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test 
the product claimed to be defective. Items claimed to be defective and are determined by Seller to be non-
defective are subject to a $30.00 per hour inspection fee. This warranty constitutes the Seller’s sole liability 
hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise stated 
in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular 
purpose.

LIAF005-1

Patent No. 424,953

7313 William Barry Blvd., North Syracuse,  NY  13212

(

Toll Free

) 800-365-5525     (

Phone

) 315-233-5266     (

Fax

) 315-233-5276

www.icmcontrols.com

Setting the Setpoint Temperature

1.  Place 

Off/Heat

 switch in the 

Heat

 position.

2.  Press the 

down

 or 

up

 button a single time to see the 

current temperature

 setting.

3.  Press the 

down

 or 

up

 button until the 

desired temperature

 setpoint displays.

4.  The new temperature setpoint is automatically saved in memory. After 5 seconds, the display 

returns to showing the current room temperature.

1.  Remove cover from remote sensor housing.
2.  Select an appropriate location for mounting the remote sensor.
3.  Mount remote sensor unit using hardware provided.
4.  Install two conductor shielded wires between remote sensor and thermostat. Shielded wire must be 

used. Do not run remote sensor wire in conduit with other wires.

  • 

Wire 1

 should run between the S1 terminal on the thermostat and the S1 terminal on the remote sensor

  • 

Wire 2

 should run between the S2 terminal on the thermostat and the S2 terminal on the remote sensor

  •  Connect the shielding of the wire to the S2 terminal on the thermostat

5.  Disable the main sensor on the thermostat by cutting it from the circuit board.

Remote Sensor Installation (Optional)

S1

G

W

S2

R

SC1600L/VL Wiring Diagrams

2-Wire, Single Transformer or Millivolt

Heating Only

Zone Valve/Damper Motor System

3-Wire, Zone Valve/Damper Motor System

2-Wire, Zone Valve/Damper Motor System

 Use 

appropriate 

size, single 
pole/double 
throw relay

24 

VAC

24 

VAC

 

Note:

 

Differential temperature may need to be increased for zone/

damper systems.

Installing and Changing Batteries

If your LCD is blank or displaying 

LO BAT

, the batteries are not installed or need to be changed. We 

suggest you change the batteries at least once a year, or whenever the 

LO BAT

 warning displays. 

 

Note:

 

After installing new batteries, you have to reset the room temperature setting and the 

differential setting. 

1.  Move the 

Off/Heat

 switch into the 

Off

 position.

2.  Remove the cover, and install the two “AA” alkaline batteries. Proper battery installation is 

important! Make sure the positive ends of the batteries match the positive terminals in the battery 

compartment. 

If the display is on, the batteries are installed properly.