10-1     Introduction to Radiometry

The basic reason for employing image processing programs when analyzing IR 

images is to have a fast and comprehensive means to determine the information 

content of an image in numerical terms. Radiometry is considered the base from 

which to conduct this analysis. 

Typically, converting the gray scale values to values of temperatures requires 

either a calibration of individual cameras or field calibration data. The method 

for calibrating images provided in this program is camera dependent because 

temperature  calibration  data  is  collected  through  an  advanced  calibration 

process at the factory and installed within the software program. 

IR Flash Pro looks for a very specific file in its structure and mates that with the 

camera serial number automatically read by the program. If this software cannot 

match the camera to the calibration file, the user cannot perform temperature 

analysis on the data. Contact customer service if there is an issue.

IF YOUR PACKAGE INCLUDES ADDITIONAL LENSES A SEPARATE CALIBRATION 

IS REQUIRED FOR EACH LENS. CONTACT CUSTOMER SERVICE IS THERE IS AN 

ISSUE.

10-2    Radiometry Correction 

The accuracy of temperature conversion is also dependent on the physics of the 

scene. These physical properties include humidity, emissivity and reflection of 

the target, the transmission in the intervening atmosphere, and the background/

foreground temperature within the scene. 

Information for an image is stored in the Project Information/Zones area and can 

be retrieved by clicking the drop-down tab next to “Image”. ROI data is stored 

under  “Zones”. 

The  dialog  box  shown  below  allows  users  to  offset  potential 

errors 

by typing precise values into the input field next to the property

:

Use the input fields 

to enter information 

and numerical data.

Users can include data 

in  reports.  To  toggle 

data  on/off  click    the 

squares. Boxes are 

green when selected. 

IMAGE DATA, I.E. INFORMATION FOR THE ENTIRE IMAGE, IS SEPARATE FROM 

REGION  OF  INTEREST  DATA,  INFORMATION  STORED  IN  THE  ROI  CREATED 

BY  THE  USER.  VISIT  THE  APPROPRIATE  DROP-DOWN  TAB  TO  INCLUDE 

PREFERRED INFORMATION IN THE REPORT.

10.

Radiometry

Содержание FMX 300X P Series

Страница 1: ...T ON IMPORTANT SAFETY INFORMATION INSIDE 2105 W Cardinal Dr Beaumont TX 77705 ICI cameras fall under US Federal Law and Export Control For more information contact us 409 861 0788 sales infraredcamera...

Страница 2: ...FMX 300X P SERIES USER MANUAL 2 Revision History 02 2024 001 Document created...

Страница 3: ...chnical Specifications 11 4 1 Industrial Specifications 11 4 2 Lens Options 13 4 3 Operating Distance 13 Structure 15 5 1 Appearance and Definitions of Housing Interface 15 Package Includes 16 Quick S...

Страница 4: ...0 10 3 Histograms Graphs 31 Troubleshooting 32 11 1 Camera s not showing camera s lagging or software crashing 32 11 2 Thermal imager shuts off unexpectedly 32 11 3 No thermal image 32 11 4 Camera out...

Страница 5: ...n permission of Infrared Cameras Inc The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without pr...

Страница 6: ...The crossed out wheeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All loca...

Страница 7: ...nergy emitted from the first 1 1000th of an inch of a subject Environment of use industrial and petrochemical buildings electrical plants security rooms science labs animal reserves as well as environ...

Страница 8: ...FMX 300X P SERIES USER MANUAL 8 2 9 Training To read about infrared training visit https infraredtraininginstitute com...

Страница 9: ...where they will be tread upon or pressed especially the connecting points leading from the plug power socket or other unit Ensure the device is firmly affixed to when installing on walls or ceilings...

Страница 10: ...torage the original packaging box must be used When transporting the camera do not lift carry or pull the device by the cable Lifting carrying or pulling the device by the cable may affect the waterpr...

Страница 11: ...Array UFPA VOx Pixel Pitch 12 m Focal Length Lens dependent FOV Lens dependent IFOV Lens dependent Focus Fixed Spectral Band 8 m to 14 m Thermal Sensitivity NETD 40 mK 0 04 C at 25 C 77 F Frame Rate 5...

Страница 12: ...G 711u AAC PCM Image Format JPG Image Polarity 20 options Image Modes IR fusion ICI Dual Vision visible picture in picture Memory MicroSD card up to 256 GB Digital Camera 5 MP 2560 x 1920 1 2 8 progre...

Страница 13: ...tion Vehicle Human Vehicle Human Vehicle Human 9 1 mm 1163 m 379 m 291 m 95 m 145 m 47 m 13 mm 1661 m 542 m 415 m 135 m 208 m 68 m 19 mm 2428 m 792 m 607 m 198 m 303 m 99 m 25 mm 3194 m 1042 m 799 m 2...

Страница 14: ...3 12 ft the height is 1 4 m 4 59 ft and the critical distance is 2 3 m 7 55 ft According to the Johnson criterion of infrared images suppose The detection target needs to be imaged at least 1 5 pixels...

Страница 15: ...MX 300X P SERIES USER MANUAL 15 5 1 Appearance and Definitions of Housing Interface 5 Structure 1 Sun Shield 2 Germanium Lens 3 Reset Button 2 1 4 5 6 3 4 Memory Card Slot 5 Memory Card Cover 6 Bracke...

Страница 16: ...ES USER MANUAL 16 6 Package Includes ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION FMX 300X Screws x3 Alignment Guides Anchors x3 Hex Wrench Waterproofing K...

Страница 17: ...INSTALLATION SITE IS A CONCRETE WALL OR CEILING FIRST INSTALL EXPANSION SCREWS THEN INSTALL THE BRACKET THE INSTALLATION HOLES OF THE EXPANSION SCREWS NEED TO BE IN LINE WITH THE BRACKET THE DEVICE HA...

Страница 18: ...according to the markers on the alignment guide Insert the expansion screws into the drilled holes The recommended depth is 25mm C D Open a 36 hole with A as the center of the circle according to the...

Страница 19: ...ONCRETE WALL OR CEILING FIRST INSTALL EXPANSION SCREWS THEN INSTALL THE BRACKET THE INSTALLATION HOLES OF THE EXPANSION SCREWS NEED TO BE IN LINE WITH THE BRACKET IF THE INSTALLATION SITE IS A WOODEN...

Страница 20: ...rk port and insert the network cable into the network port F H Place the rubber ring on the network cable between the main body of the waterproof cover and the fastening nut Align the notch of the net...

Страница 21: ...ALARM IN1 and PIN 2 ALARM IN2 are alarm input PIN 3 is GND P6 is alarm output ALARM OUT pin_1 ALARM OUT1 and in_2 ALARM COM1 are channel 1 alarm output pin_3 ALARM OUT2 and pin_4 ALRAM COM2 is channe...

Страница 22: ...AND BEST IMAGE QUALITY THIS TIME CAN OFTEN VARY BY ENVIRONMENTAL CONDITIONS IT IS BEST TO WAIT A MINIMUM OF 10 MINUTES FOR THE DEVICE TO COMPLETELY WARM UP Use the Hex Wrench to loosen the lock nuts i...

Страница 23: ...the figure below The camera can be connected to alarm switch signal 0 DC 5V input and switch output no voltage An external power supply is required when connecting the alarm The specific wiring method...

Страница 24: ...FMX 300X P SERIES USER MANUAL 24 C Use a standard screwdriver replace and the memory bay cover and screws...

Страница 25: ...et a gateway as this is a direct connection from the computer to the cameras with no router Be sure the static IP address is set by doing the following 1 Click on Windows icon 2 Click on Settings 3 Cl...

Страница 26: ...tup A copy of the software is provided on the Software USB Drive Documentation can be found online on the IR Flash Pro web page under the Downloads section or at this address https infraredcameras com...

Страница 27: ...replace the cloth and repeat the wiping process 9 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components It is recommended to disinfect the camera s...

Страница 28: ...mer service if there is an issue IF YOUR PACKAGE INCLUDES ADDITIONAL LENSES A SEPARATE CALIBRATION IS REQUIRED FOR EACH LENS CONTACT CUSTOMER SERVICE IS THERE IS AN ISSUE 10 2 Radiometry Correction Th...

Страница 29: ...To set the emissivity enter a value from 0 01 to 1 0 in the input box The accompanying table gives the typical emissivity of important materials Material Emissivity Water 96 Stainless steel 14 Alumin...

Страница 30: ...r water there may be no perceived thermal difference between the horizon and the water i e the horizon can seem to disappear Users can change their angle by changing where they stand or by attaching a...

Страница 31: ...e screen plots image information in the form of a histogram or a 3D rendering It also allows users to visualize the temperature data over time for any all ROIs placed on the image the last image below...

Страница 32: ...ss is correct Default IPv4 of 192 168 10 110 Default subnet mask of 255 255 255 0 Restart computer Verify that correct software is installed Uninstall reinstall software running as administrator Verif...

Страница 33: ...ce has sufficiently acclimated to the environment before taking measurements Ensure the camera has been powered on for several minutes Device is at proper height Ensure device is in focus Adjust emiss...

Страница 34: ...gineers scientists inspectors and operators in space power companies medical pulp and paper food industry research and development and various process industries You can see our products and services...

Отзывы: