Parameters Setup
Parameters Setup
Press
<TAB/SYS>
button
on the initial interface to enter the
SYSTEM MENU
interface, setting and testing of the system
parameters, storage and servo can be completed on this interface.
Charger Setup
After setting all parameters, click “
Save
” to save and return to the previous interface.
Temp. & Fans Setup
Select
SYSTEM MENU
→
Temperature&Fans
to enter the setup interface
When the charger’s internal temperature reaches the
ON Temperature
, the fan will start automatically to dissipate heat,
and adjust speed automatically depends on the temperature increasing or decreasing. When the temperature exceeds the
Power Reduce
temperature, the charger will stop increasing (temp. shown in orange) by reducing the highest power limit.
When the temperature reaches
Shut Down
temperature, the charger will shut down. [When temp. >
Shut Down
-3, the
temperature is shown flashing in red]. When the temperature is lower to the
ON Temperature
, the fan will keep running
within the setting time of
OFF Delay Time
.
1. Charger Setup Menu
2.Temp. & Fans Setup
3.Beep Tone
4. LCD Screen
5.USB PD
6. Output Power Setup
7.Input Limit
8.Save & Load Configuration Setup
9.Language Setup
10. Calibration
11.Extra- Function
12.Log Files Manage
13. Servo Test
14. Pulse Test
1
2
3
4
5
6
7
8
9
11
12
13
14
10
1:
Temperature
:
Unit
:
Celsius (default), Fahrenheit
Shut Down
:
65℃-80℃; default: 80℃
Power Reduce
:
-5℃-20℃; default: -10℃
2:
Cooling Fans
:
ON Temperature
:
30℃-50℃; default: 40℃
OFF Delay Time
:
0Min-10Min; default: 2Min