10. Error Type
●
ICE
●
NO
WAER
●
DRAIN
Ice Making
L
When the operation switch is
switched to the 'ICE' position
Washing
B
When the operation switch is
changed to 'WASH', the 'ICE' lamp
blinks
(every 1 second)
Drainage stops and goes out when the
operation switch is switched to the 'off'
position
Ice Full
(Storage bin)
B
When the storage bin is full of ice
(Lights on every 2 seconds, turns off
for 1 second repeatedly)
When the ice full sensor detects the release
temperature, the lamp turns off
Drain valve
operating
L
When the drain valve opens
Water supply
error
B
When water level is not detected by
the water level sensor due to
no water supply for 2 minutes.(Er15)
Water supply pressure check
Water level sensor check
Start operation after action
Water drain
error
B
If the lower limit water level sensor is
not detected within 2 minutes as the
drain valve operates(Er16)
Replacement of water wevel wensor
Check drain valve operation
Start operation after action
Evaporator
temperature
error
B
B
B
When the Evaporator temperature is
32℉ or more after 30 minutes
passed during the ice making(Er01)
Check refrigerant leakage
Check sensor and attachment abnormality
Resupply power after resolving cooling
problem
Evaporator
temperature
error
B
When the Evaporator temperature is
32℉ or more after 10 minutes
passed during the ice making(Er03)
Check refrigerant leakage
Check sensor and attachment abnormality
Resupply power after resolving cooling
problem
Ice full sensor
error
B
B
When the ice full temperature sensor
in the storage bin is disconnected or
shorted
Evaporator
temperature
sensor error
B
B
When the EVA temperature sensor at
the evaporator outlet is disconnected
or shorted
Air
temperature
sensor error
B
B
When the air temperature sensor in
front of the condenser is
disconnected or shorted
Evaporator
freezing
L
L
L
When the evaporator outlet
temperature drops below the set
temperature for 2 minutes while the
ice maker is running(Er25)
Occurs when the ambient temperature is low
Operate when the ambient temperature is
over 50℉
* L:
Lamp On,
F
: Lamp Blinking
Lamp
Causes
Current
Condition
Action / Release
Check sensor and attachment abnormality
Start operation after sensor part repair