1.
With Water Curtain closed, Dump Valve and Water Valve are energized for 15 seconds.(set time) With brackish water pumped
from the Sump Trough, Water Pump and Dump Valve are de-energized.
2.
After 15 seconds Dump Valve is de-energized. But Water Valve is energized until water level sensor reaches high level plus 15
seconds. Fan motor energized after 5 seconds with Water Curtain closed.
3.
When water contacts Ice Thickness Sensor for 7 continuous seconds, the machine enters defrost.
4.
Hot Gas Valve are energized for approximately 50 seconds. At this time, the Pump Motor and the Water supply valve are de-
energized.
5.
Compressor and Hot Gas Valve continue to defrost evaporator until ice falls from evaporator plate.
6.
Ice falling from evaporator cause Water Curtain open then closes when ice clears the Evaporator signaling defrost termination.
7.
With the Curtain closed, the machine begins another cycle.
•
After shut down due to full bin level and lighting of “Full Lamp”, removal of ice from bin will cause the Curtain to close wh
ich c
loses the Curtain Switch and energize the machine with the same steps as “INITIAL START
-
UP”.
•
* Normal continuous operation starts a new cycle with steps 1 through #7.
NORMAL CONTINUOUS SEQUENCE OF OPERATION DURING ICE MAKING MODE IM SERIES
Содержание IM Series
Страница 1: ...INSTALLATIONS SERVICE OPERATIONS FOR IM 350 350 22 460 460 22 550 550 22 680 1100 SERIES ICE MAKERS...
Страница 6: ...DOOR ON HINGE ACCESS TO DIAGNOSTICS PANEL Door can rest on top of machine if needed...
Страница 8: ...Non Corrosive Platform...
Страница 11: ...NEW WATER DISTRIBUTION TUBE REMOVABLE NO TOOLS...
Страница 12: ...DISTRIBUTOR TUBE REMOVED FOR CLEANING WATER SUPPLY FROM PUMP WHEN DISTRIBUTOR TUBE IS REMOVED...
Страница 14: ...CLOSE UP OF CURTAIN HOLDERS DISTRIBUTOR TUBE THUMB KNOBS...
Страница 15: ...ADJUSTABLE FLUSH FOR DRAIN WATER TO REDUCE SCALE ADJUSTABLE FLUSH CAN HELP TO REDUCE CLEANING COSTS MAINTANENCE...
Страница 17: ...WATER PUMP MOTOR OUT OF WET ZONE EASY ACCESS TO PUMP...
Страница 19: ...ACCESS PORTS IM Series Indication label of high pressure Low pressure nipple of compressor...
Страница 20: ...Replacing a pressure switch Use a Pinch Off tool when possible...
Страница 21: ...MAGNETIC FRAME CLEANABLE CONDENSER AIR FILTER...
Страница 22: ......
Страница 28: ...WATER REFRIGERANT FLOW...
Страница 29: ...HARVEST CYCLE...
Страница 31: ...PLASTIC COVER PIECE WITH KIT BAFFLE TO BE FURNISHED BY DISPENSER MFG...
Страница 37: ......
Страница 38: ...Error Code Indicator Lights Diagnostics FNB BOARD ERROR CODE INFO...
Страница 39: ...FNB BOARD ERROR CODE INFO...
Страница 41: ...IM SERIES WIRING DIAGRAM...
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ...Thank You...