13. Control Function
It is preset by the manufacturer. Very little adjustment is required.
Agitation standard time is 2 seconds every 4 hours. If the instrument is installed in a low
temperature environment, adjust it to agitate more frequently. However, if the ice produced by
the ice maker is cloudy and brittle, adjust it to be less agitated.
To adjust agitation time, open
the control box and adjust the
highlighted part of the PCB