Maintenance Suggestions
EVERY 3
YEARS
●
Inspect the inside of the evaporator cylinder for wear, cracks, etc.
●
Inspect the auger for wear, cracks, etc. & replace if necessary.
●
Inspect extruder for wear, cracks, etc.
●
Replace the mechanical seal.
●
Replace the housing o-ring.
●
Inspect the coupling for wear, cracks, etc. & replace if necessary.
●
Lift coupling from gearbox and inspect for wear, cracks, etc.
Preventative Maintenance - Technicians Only
Mechanical Seal
Auger
Housing
Coupling
O-Ring (red)
Evaporator Cylinder
Suggested Maintenance Schedule
Maintenance intervals will vary with ambient & water conditions.
These are only suggestions.