ICE TECH SS / SP Technical Service
Manual
17
Bear in mind the previous considerations if the premises where the machines is located are very
dusty, or smoky. If possible make arrangements so that the machine may be moved frontwise in
order to carry out maintenance.
4.1. Recommended placement of unit
IMPORTANT!
ICETECH machines are intended to operate at room temperature between 5°C and 43°C and
with water temperature ranging between 5°C and 35°C. You may encounter evaporator/gearbox
malfunctions should the machine run at temperatures below the recommended minimum. When
running above maximum recommended temperatures you can expect shorter compressor life and
decreased production.
Air-cooled units receive air input via front of machine and expel air through rear grille.
IMPORTANT!
If front and/or rear ventilation is inadequate, obstructed, or in close proximity to other heat
producing machinery, use of a water-cooled unit is strongly recommended.
The above mentioned also applies should unit be installed in an area where dust, smoke, or other
airborne pollutants may be present. Units—especially air-cooled ones—should not be installed in
kitchens. To facilitate access to condenser and/or water pressure valve, allow sufficient space at
front of the machine. Ensure that flooring is firm and even.
4.2. Water and Drainage
Water quality influences ice hardness, flavour, and quality as well as condenser life.
Keep in mind the following points:
a) WATER IMPURITIES: Major impurities are eliminated by filters provided. Filters should be
cleaned regularly depending on purity of water. For minor impurities we recommend
installing a 5-micron filter.
b) WATER WITH MORE THAN 500 PPM: Ice will be less hard and tend to adhere. Lime
deposits may impede proper functioning. In water cooled models, condenser obstruction
is likely. Installation of a high quality water softener is recommended.