CONNECTION DIAGRAM:
The location must allow enough clearance for water drain and electrical connections in the rear of the ice
machine
2.5.- WATER SUPPLY CONNECTION
The quality of the water supplied to the ice machine will have an impact on the time between cleanings
and ultimately on the life of the product (mainly in water cooled units). It also will have a remarkable
influence on the appearance, hardness and flavor of the ice.
Local water conditions may require treatment of the water to inhibit scale formation, improve taste and
clarity. If you are installing a water filter system, refer to the installation instructions supplied with the filter
system.
Pressure should be between 0.1MPa and 0.6MPa (1 and 6 bar). If pressure overpasses such values,
install a pressure regulator.
The water connection needs to be dedicated (only piece of equipment hooked to the water line).
ATTENTION:
The machine shall be plumbed (with adequate backflow protection) according to
applicable national and local regulations.
2.6.-DRAIN CONNECTION
2.6.1.- GRAVITY DRAIN
Drainage should be located lower to the machine level, 150mm minimum.
It is convenient that the drain hose is 30mm inside diameter and with a minimum gradient of 3cm/metre,
see figure.