8.3 Physical characteristics 

Characteristics

 

Description

 

        Dimensions (H x W x D)

 

    200mmx90mmx42mm    
212mmx100mmx55mm(with holster)

 

          Weight (with battery)

 

            0.4Kg

 

          With holster

 

            0.6Kg

 

 

8.4 Environmental characteristics

 

Characteristics

 

Description

 

    Temperature operating

 

    0 to + 50°C 

 

                                            Non-Operating

 

    -20 to + 60°C 

 

        Humidity (operating)

 

    < 80% R.H.

 

        Altitude Operating

 

    2,222 m (7290 ft.)

 

                                            Non-Operating

 

    12,300 m (40354 ft.)

 

    Vibration & shock Operating

 

    MIL-T-28800E TYPE II Class 5     

2.66gRMS, 5 to 500 Hz, 3axes     
(10 minutes each)

 

        Dust / Water Protection IP Rating

 

        IP 64.

 

        Indoor Use

 

8.5 Certifications and compliances

 

Safety

 

        Designed to IEC 1010-1, UL3111-1 and CSA specifications

 

Input rating

 

    1000V DC Category 

 

    600V DC Category 

 

        750V AC Category 

 

        600V AC Category 

 

Over voltage   

category

 

        CAT 

  : Distribution level mains, fixed installation.

 

        CAT 

  : Local level mains, appliances, portable equipment.

 

        CAT 

: Signal level, special equipment or parts of                       

equipment, telecommunication, electronics.

 

  Pollution Degree 2

 

        Do not operate in environments where conductive pollutants  

may be present.

 

 

 

Содержание MD-6540

Страница 1: ...MANUAL DE INSTRU ES DO MULT METRO DIGITAL MODELO MD 6540 vers o em Ingl s Leia atentamente as instru es contidas neste manual antes de iniciar o uso do instrumento...

Страница 2: ...2 DATA LOG IN 9 4 12 3 DATA LOG OUT 9 4 12 4 9 4 12 5 9 4 13 DTGIT 10 5 OPERATION 11 5 1 VOLTAGE MEASUREMENTS 11 5 2 Milli VOLTAGE MEASUREMENTS AC DC AC DC 12 5 3 OHM AND LOW VOLTAGE OHM MEASUREMENTS...

Страница 3: ...ble Insulated High Voltage Specific precautions Use proper Fuse To avoid fire hazard use only the fuse type and rating specified for this product Do not operate without covers To avoid personal injury...

Страница 4: ...type of meter has own features described in this manual The following list provides a comparison of the features between meters FUNCTION 107N 109N DC Voltage AC Voltage mV Voltage Resistance Lo Ohm D...

Страница 5: ...for dBm Delta mode Hazard Warning Storage and Recell up to 1000 Memories Low Battery Indicator MAX MIN AVG Peak Hold 0 5ms Data Log up to 40k memories 6K True RMS AC DC AC VAC Hz Dual Display Water Du...

Страница 6: ...EW Figure 1 1 Input connectors 2 Measurement function dial Black labels are the initial settings blue labels are selected by the blue button 3 Function buttons 4 Data log features 5 LCD display with d...

Страница 7: ...istance indicator 5 Auto hold indicator 6 Peak hold indicator 7 Maximum Minimum and Average indicators 8 Main display unit indicators 9 Sub display unit indicators 10 STORE and RECALL indicator 11 Hig...

Страница 8: ...Fahrenheit dB Decibel 1V ref Celsius dBm Decibel 1mW on 600 ohm G gega n nano 4 BUTTONS FUNCTION Prediction Buzzer beeps once for every key press Buzzer beeps twice for every invalid key press Figure...

Страница 9: ...ging range escapes Switches to Manual range mode when press this key under Resistance Capacitance and frequency functions 2G range has no this function 9 position has no this function 4 5 BLUE The blu...

Страница 10: ...ice Again 2 sec press on this key in this mode escaps Power up with PEAK key pressing to clear stores 4 11 RECALL Pressing REL key for 2 enables RECALL function Again 2 sec press on this key in this m...

Страница 11: ...with PAUS on sub display for log rate re setting While data log in performing the sub display is blinking for storing indication When stores data at 40Kth 6Kth for 107N data log in stops the bar is fu...

Страница 12: ...2 sec pressing excapes Press under this mode toggles 20000 4000 count modes Rotate to power OFF then on to reset to 20000 count mode default This key is not available on following items 4 13 1 200M an...

Страница 13: ...eads The AC and AC DC measurements provide a true RMS measurement In AC mode the frequency of the measured signal 20 of full scale is displayed on sub display 5 2 Milli VOLTAGE MEASUREMENTS AC DC AC D...

Страница 14: ...Choose AC DC or AC DC Connect leads The AC and AC DC measurements provide a true RMS measurement In AC mode the frequency of the measured signal 20 of full scale is displayed on sub display...

Страница 15: ...LV Connect leads CAUTION Remove all power from the circuit before connecting the test leads LV setting reduces the maximum test voltage level to about 0 5V to avoid turning on semiconductor devices R...

Страница 16: ...5 4 DIODE TEST Set dial Choose diode test Connect leads Forward bias Good 0 4 to 0 9V Bad o or 2 0V Reverse bias Good OL Bad 2 0V...

Страница 17: ...CAUTION Remove all power from the circuit before connecting the test leads Remove individual components from circuitry for best results 5 5 CONTINUITY CHECK Set dial Choose diode test Connect leads...

Страница 18: ...CAUTION Remove all power from the circuit before connecting the test leads The beeper sounds if the resistance of the circuit is less than 50 5 6 CURRENT MEASUREMENTS AC DC AC DC Set dial...

Страница 19: ...easurements 10 to 20A to 30 seconds and allow two minutes of cooling between measurements Do not connect to circuits with 600V The AC and AC DC measurements provide true RMS In AC mode the frequency o...

Страница 20: ...itance measurements CAUTION Remove all power from the circuit and discharge Capacitor to be measured before connecting the test leads Remove individual components from circuit for best results 5 8 FRE...

Страница 21: ...Connect leads The duty factor displays the percent of the signal that is high 5 9 TEMPERATURE MEASUREMENTS Set dial...

Страница 22: ...Choose Celsius or Fahrenheit Choose Celsius or Fahrenheit Connect leads...

Страница 23: ...uard The meter beeps continuously and displays ProbE if a probe is inserted in a current input connector and a measurement other than current is selected 6 3 Buzzer A single beep indicates correct ope...

Страница 24: ...layed Low voltage indicator is indicated Automatic power off time Automatic backs lit off 15minutes Power source One 9V dry cell battery Maximum input voltage 1000V 750V AC CAT between V and COM Maxim...

Страница 25: ...0 0 70 80 1 00 80 2V 40Hz 100Hz 100Hz 1KHz 1KHz 10KHz 10KHz 20KHz 20KHz 50KHz 50KHz 100KHz 0 70 50 1 00 50 2 00 60 3 00 70 5 00 80 10 00 100 0 70 50 1 00 50 2 00 60 3 00 70 5 00 80 10 00 100 20V 40Hz...

Страница 26: ...C F 1 4 to 3 3 0 addition error for C F from 3 to 4 2 CURRENT DCA 107N 109N 20mA 200mA 0 20 40 0 20 40 2A 10A 0 20 40 0 20 40 ACA 107N 109N 20mA 200mA 2A 10A 40Hz 500Hz 0 80 50 0 80 50 20mA 200mA 2A...

Страница 27: ...107N 2K 20K 200K 0 60 20 2M 0 60 50 20M 7 00 50 200M 7 00 20 excludes DIGIT switch Resolution 0 01 in the 200 range Open Circuit Voltage 3 3V Open Circuit Low Voltage 0 6V Input Protection 600V rms 5...

Страница 28: ...0Hz range Accuracy 0 01 10 0 01 50 for 20Hz Range Sensitivity 0 5Vp p for 5Hz 1MHz Min Frequency 5Hz Input Protection 600V rms 9 DUTY FACTOR Excludes DIGIT switch Range 20 80 Resolution 0 1 Accuracy 1...

Страница 29: ...ng MIL T 28800E TYPE II Class 5 2 66gRMS 5 to 500 Hz 3axes 10 minutes each Dust Water Protection IP Rating IP 64 Indoor Use 8 5 Certifications and compliances Safety Designed to IEC 1010 1 UL3111 1 an...

Страница 30: ...3 EEC for Product Safety Compliance was demonstarted to the following specifications as listed in the official Journal of the European Communites En 55011 Class A Radiated and Conducted Emissions EN 5...

Страница 31: ...chemical cleaning agents BATTERY REPLACEMENT refer to Figure 4 1 Disconnect the test leads from any circuit under test and turn off meter 2 Remove the test leads from meter 3 Loosen the plastic screws...

Страница 32: ...Case Figure 5 Fuse1 1A 600v Battery Cover Screw Screw Fuse2 15A 600v Top Case Figure 4 Figure 5 Screw Screw Battery Cover Battery Connector 9V Battery Top Case Bottom Case Screw Screw Screw Battery C...

Страница 33: ...10 ACCESSORIES 107N Gift Box Meter Holster Tilt Battery 9V Manual Test Leads Aligator Clip Temp Socket K Type Sensor 50BK RS 232 Cable with Adapter DB9M to DB25F Option Carrying Case Option...

Страница 34: ...www icel manaus com br icel icel manaus com br...

Отзывы: