Icel Manaus GV-2005 Скачать руководство пользователя страница 3

 

 

 

General

 

Warranty

 

ICEL

 

MANAUS

 

warrants

 

that

 

the

 

product

 

will

 

be

 

free

 

from

 

defects

 

in

 

materials

 

and

 

workmanship

 

for

 

a

 

period

 

of

 

3

 

years

 

(1

 

year

 

for

 

accessories)

 

from

 

the

 

date

 

of

 

purchase

 

of

 

the

 

product

 

by

 

the

 

original

 

purchaser

 

from

 

the

 

ICEL

 

MANAUS

 

Company.

 

This

 

warranty

 

only

 

applies

 

to

 

the

 

original

 

purchaser

 

and

 

is

 

not

 

transferable

 

to

 

the

 

third

 

party.

 

If

 

the

 

product

 

proves

 

defective

 

during

 

the

 

warranty

 

period,

 

ICEL

 

MANAUS

 

either

 

will

 

repair

 

the

 

defective

 

product

 

without

 

charge

 

for

 

parts

 

and

 

labor,

 

or

 

will

 

provide

 

a

 

replacement

 

in

 

exchange

 

for

 

the

 

defective

 

product.

 

Parts,

 

modules

 

and

 

replacement

 

products

 

used

 

by

 

ICEL

 

MANAUS

 

for

 

warranty

 

work

 

may

 

be

 

new

 

or

 

reconditioned

 

like

 

new

 

performance.

 

All

 

replaced

 

parts,

 

modules

 

and

 

products

 

become

 

the

 

property

 

of

 

ICEL

 

MANAUS.

 

In

 

order

 

to

 

obtain

 

service

 

under

 

this

 

warranty,

 

Customer

 

must

 

notify

 

ICEL

 

MANAUS

 

of

 

the

 

defect

 

before

 

the

 

expiration

 

of

 

the

 

warranty

 

period.

 

Customer

 

shall

 

be

 

responsible

 

for

 

packaging

 

and

 

shipping

 

the

 

defective

 

product

 

to

 

the

 

service

 

center

 

designated

 

by

 

ICEL

 

MANAUS,

 

and

 

with

 

a

 

copy

 

of

 

customer

 

proof

 

of

 

purchase.

 

This

 

warranty

 

shall

 

not

 

apply

 

to

 

any

 

defect,

 

failure

 

or

 

damage

 

caused

 

by

 

improper

 

use

 

or

 

improper

 

or

 

inadequate

 

maintenance

 

and

 

care.

 

ICEL

 

MANAUS

 

shall

 

not

 

be

 

obligated

 

to

 

furnish

 

service

 

under

 

this

 

warranty

 

a)

 

to

 

repair

 

damage

 

resulting

 

from

 

attempts

 

by

 

personnel

 

other

 

than

 

ICEL

 

MANAUS

 

representatives

 

to

 

install,

 

repair

 

or

 

service

 

the

 

product;

 

b)

 

to

 

repair

 

damage

 

resulting

 

from

 

improper

 

use

 

or

 

connection

 

to

 

incompatible

 

equipment;

 

c)

 

to

 

repair

 

any

 

damage

 

or

 

malfunction

 

caused

 

by

 

the

 

use

 

of

 

non

ICEL

 

MANAUS

 

supplies;

 

or

 

d)

 

to

 

service

 

a

 

product

 

that

 

has

 

been

 

modified

 

or

 

integrated

 

with

 

other

 

products

 

when

 

the

 

effect

 

of

 

such

 

modification

 

or

 

integration

 

increases

 

the

 

time

 

or

 

difficulty

 

of

 

servicing

 

the

 

product.

 

 

 

Please

 

contact

 

the

 

nearest

 

ICEL

 

MANAUS's

 

Sales

 

and

 

Service

 

Offices

 

for

 

services

 

or

 

a

 

complete

 

copy

 

of

 

the

 

warranty

 

statement.

 

For

 

better

 

after

sales

 

service,

 

please

 

visit

   

www.ICEL

‐ 

MANAUS.com.br

   

and

 

register

 

the

 

purchased

 

product

 

online.

   

 

Excepting

 

the

 

after

sales

 

services

 

provided

 

in

 

this

 

summary

 

or

 

the

 

applicable

 

warranty

 

statements,

 

ICEL

 

MANAUS

 

will

 

not

 

offer

 

any

 

guarantee

 

for

 

maintenance

 

definitely

 

declared

 

or

 

hinted,

 

including

 

but

 

not

 

limited

 

to

 

the

 

implied

 

guarantee

 

for

 

marketability

 

and

 

special

purpose

 

acceptability.

 

ICEL

 

MANAUS

 

should

 

not

 

take

 

any

 

responsibilities

 

for

 

any

 

indirect,

 

special

 

or

 

consequent

 

damages.

 

Содержание GV-2005

Страница 1: ...Economical Type 1 channel Arbitrary Waveform Generator User Manual GV 2005...

Страница 2: ......

Страница 3: ...apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care ICEL MANAUS shall not be obligated to furnish service under this warranty a to repair damag...

Страница 4: ...Output Sine Signals 11 To Set the Frequency Period 11 To Set the Amplitude 12 To Set the Offset 12 To Set the High Level 12 To Set the Low Level 12 To Output Square Signals 12 To Set the Duty Cycle 1...

Страница 5: ...or 31 To Set the Screen Saver 31 To Set the Counter Only for the model with F 31 To Set Output Parameter 32 To Set the Output Load 32 To Set the System 33 Language Setting 33 Power On Setting 33 To Re...

Страница 6: ...grounded The product must be grounded properly before any connection with its input or output terminal Check all Terminal Ratings To avoid fire or shock hazard check all ratings and markers of this pr...

Страница 7: ...this product or other property Terms on the Product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an injury or haza...

Страница 8: ...for users Features and benefits 4 inch high resolution 480 320 pixels TFT LCD display Advanced DDS technology Max Sample rate 125 MSa s Frequency resolution 1 Hz Vertical resolution 14 bits 8192 wave...

Страница 9: ...Start This chapter will deal with the following topics mainly Front Rear Panel Overview User Interface Overview How to Implement General Inspection How to Adjust the Foot Stools How to Implement Power...

Страница 10: ...ed to select file location or switch the character of the soft keyboard when entering file name In Sweep and N Cycle Burst if you choose Source as Manual every time you press this knob the generator w...

Страница 11: ...nly for the model with F Generate the Modulated waveforms Burst Only for the model with F Generate burst for Sine Square Ramp Pulse and Arbitrary waveform Sweep Only for the model with F Sweep Sine Sq...

Страница 12: ...ept an external clock signal or to accept the input signal of counter Accepting input signal of counter is only for the model with F see page 35 To Set the Counter Ext Trig Burst Fsk In connector Only...

Страница 13: ...cribed in the Appendix A Enclosure of this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged p...

Страница 14: ...hange the voltage scale of the instrument do the following steps 1 Turn off the power button at the front panel and remove the power cord 2 Regulate the Power Switch to the desired voltage scale Power...

Страница 15: ...ine Signals How to Output Square Signals How to Output Ramp Signals How to Output Pulse Signals How to Output Noise Signals How to Output Arbitrary Signals How to Output DC How to Generate the Modulat...

Страница 16: ...the Sine setting menu on the right The parameters of Sine waveform are Frequency Period Amplitude High Level Offset Low Level You can operate the menu by using the menu selection buttons on the right...

Страница 17: ...set In Parameter 3 a cursor appears under the value of offset Use the knob or the number keys to set the desired value To Set the High Level Press F2 confirm whether the Hi_Level menu item is highligh...

Страница 18: ...ut signal is set to 5Vpp amplitude and 2 5V offset When the load is 50 the output signal is set to 2 5Vpp amplitude and 1 25V offset Figure 5 3 The User Interface of Square Signal Term Explanation Dut...

Страница 19: ...ating the Ramp setting menu on the right The parameters of Ramp waveform are Frequency Period Amplitude High Level Offset Low Level Symmetry You can operate the menu by using the menu selection button...

Страница 20: ...ress F4 to choose Figure 5 6 Set the symmetry of Ramp signal To Output Pulse Signals Press button to call the user interface of Pulse signal the Pulse waveform parameters can be set by operating the P...

Страница 21: ...0 of the falling edge amplitude Negative Pulse Width is the time span between thresholds of 50 of the falling edge amplitude to the next 50 of the rising edge amplitude Pulse Width is determined by Pe...

Страница 22: ...of Noise waveform are Amplitude High Level Offset Low Level You can operate the menu by using the menu selection buttons on the right To set the Amplitude High Level Offset Low Level please refer to T...

Страница 23: ...als on page 11 The Arbitrary signal consists of two types the system built in waveform and the user definable waveform Setting menu of Arbitrary signal Amplitude Load Offset Current signal Frequency P...

Страница 24: ...undHalf RoundHalf wave AbsSine Absolute value of a Sine AbsSineHalf Absolute value of half a Sine SineTra Sine transverse cut SineVer Sine vertical cut NegRamp Negative ramp AttALT Gain oscillation cu...

Страница 25: ...LFMPulse Linear FM pulse Rhombus Rhombus signal Cardiac Cardiac signal The User Definable Waveform Press button and press F5 to select Editable Wform Menu item Instruction Create Wform Create a new w...

Страница 26: ...form 2 Enter the storage path of the desired waveform file Turn the knob or press direction key to select the desired waveform file 3 Choose Recall output How to Edit a Stored Waveform 1 Enter the ope...

Страница 27: ...modulated waveform consists of two parts the Carrier Waveform and the Modulating Waveform The Carrier Waveform can only be Sine In AM the amplitude of the Carrier Waveform varies with the instantaneou...

Страница 28: ...AM Frequency The range is 2 mHz 20 kHz Internal source only 7 Press F4 to set Mod Depth The range is 0 100 Term Explanation AM Frequency The frequency of modulating waveform Mod Depth The Amplitude R...

Страница 29: ...elect the source If the source is External use the Ext Mod In connector in the rear panel to input the external signal then skip ahead to step 6 If you choose Internal continue to the steps below 5 Pr...

Страница 30: ...u can change the parameters please refer to To Output Sine Signals on page 11 Press button again to return to the Modulation mode interface 4 Press F5 to select the source If the source is External us...

Страница 31: ...form is not Sine the system will switch it to Sine automatically 3 Press button to display the waveform and parameters of the Carrier Waveform You can change the parameters please refer to To Output S...

Страница 32: ...r the Sweep mode 2 Press or button to choose the waveforms Take Sine for instance press to display the waveform and parameters You can change the parameters please refer to To set signals on page 11 P...

Страница 33: ...N Cycle Burst or to be controlled by external gated signals Gated Burst Bust can apply to Sine Square Ramp Pulse and Arbitrary waveforms Noise can not be used Term Explanation Burst Output Waveforms...

Страница 34: ...d which will not stop until a trigger event happens the knob on the front panel is pressed Note If needed Burst Period will increase to cater to the specific number of cycles For an infinite cycle Bur...

Страница 35: ...ame copy and paste To Edit the File Name In file system the user can edit the name of a file or a folder When the system needs the user to input a name an input keyboard will appear Figure 5 19 Edit t...

Страница 36: ...select Sep 2 Press F2 to switch between Comma Space Off Take the Frequency parameter for instance Comma Space Off To Set the Screen Saver The screen saver will run automatically if no operation is ta...

Страница 37: ...direction key to move the cursor left and right or press the number keys to input the desired value and choose the unit The range of trig levle is 2 5 V 2 5 V Press F5 to choose Back to previous menu...

Страница 38: ...fault Last Default means that all the settings return to default when powered Last means that all the settings return to the last one when powered To Return to Default Setting Press Utility and choose...

Страница 39: ...t Only for the model with F Default Frequency 1 kHz Count 1 Cycle Period 1 sec Phase 0 Others Default Brightness 95 Separator Comma Screen Saver time 100 minutes Load High Z Clock Source Internal Chan...

Страница 40: ...d the output Voltage of the Sync output terminal is Level Low Note When the amplitude is relatively low disabling Sync Signal can reduce the distortion in output The Instructions of the Sync Signal in...

Страница 41: ...he Burst when the burst starts the Sync Signal is Level High At the specific point when the Cycle Number ends the Sync Signal turns Level Low If the Waveform has a relative starting phase it may be no...

Страница 42: ...a PC 2 Install the driver When the Waveform Generator is turned on a dialog will appear on the PC screen and guide you to install the USB driver The driver is in the USBDRV folder under the directory...

Страница 43: ...er socket is used appropriately and in good condition the cover can be pried open with a straight screwdriver Restart the instrument after the steps above If the problem still exists please contact IC...

Страница 44: ...efinable Waveform Frequency Characteristic Max sampling rate 125 MSa s Frequency resolution is 1 Hz Sine AG051 F 1 Hz 5 MHz Square 1 Hz 5 MHz Ramp 1 Hz 1MHz Pulse 1 Hz 5 MHz White Noise 5 MHz bandwidt...

Страница 45: ...0 Duty Cycle 1 of period 5 ns Overshoot 5 Duty Cycle 50 fixed Ramp Linearity 0 1 of peak output typical 1 kHz 1 Vp p Symmetry 50 Symmetry 0 to 100 Pulse Pulse Width 100 ns to 1000 ks Accuracy 10 ns Ri...

Страница 46: ...ting Waveforms 50 duty cycle square FSK Rate 2 mHz 100 kHz Sweep Type Linear Logarithmic Carrier Waveforms Sine Square Ramp Direction Up Down Sweep Time 1 ms to 500 s 0 1 Source Source External or Man...

Страница 47: ...hare the same port as External Reference Clock Input DC coupled DC offset range 1 5 VDC 100 mHz 100 MHz 250 mVp p 5 Vp p AC DC 100 MHz 200 MHz 450 mVp p 3 Vp p AC DC AC coupled 1 Hz 100 MHz 250 mVp p...

Страница 48: ...43 Dimension 235 mm 110 mm 295 mm W H D Weight 3 kg Interval Period of Adjustment One year is recommended for the calibration interval period...

Страница 49: ...ing conditions require To clean the instrument exterior perform the following steps 1 Wipe the dust from the instrument surface with a soft cloth Do not make any scuffing on the transparent LCD protec...

Отзывы: