9081477‐01 REV D
Page 3 of 4
Figure 5: Bin Thermostat wiring
Wiring in machine as shipped
As wired with Bin Thermostat installed in series with
Bin Fill Switch
5.
Secure new red wire with supplied wire ties.
6.
Adjust the bin thermostat (see
Bin Thermostat Adjustment
section).
CIM Series Thermostat
Tube
Bracket:
1.
Install the ice deflector assembly to the ice
machine. Make sure that the end of the deflector
with the thermal well is down into the bin. Secure
with the #10 screws provided in the base.
2.
Remove the plug from the right side of the food
zone for the installation of the bin thermostat in
later steps.
Note:
The slots in the ice deflector
are designed so that the screws in the base only
need to be loosened, rather than completely
removed.
CIM Series Bin Thermostat Installation
1.
Remove control box cover & install the bin level
thermostat in holes provided on the control box or
frame.
2.
Attach provided bin thermostat harness to the
thermostat, and then route other end into the
control box. Plug into the control board connector
labeled bin thermostat.
3.
Route thermostat capillary tube so it does not
interfere with any electrical or moving
components. There is a removable plastic cap in
the right wall of the food‐zone to run the cap tube
ROUTE CAP TUBE HERE
BIN STAT MOUNTING
LOCATION
BIN STAT
CONNECTION
Figure 6: CIM Right Side View
PLUG
ICE DEFLECTOR
Figure 2: CIM Deflector Installation
DIP SWITCH