background image

How It Works                                                                                          ICEU060

Page 9

Water System

Freezing Cycle

The refrigeration process creates cold temperatures within the evaporator coils and removes heat from the
water sprayed up into the inverted ice cube cups.  When enough heat is removed, the water changes into
ice, and forms where it is the coldest: in the ice cube cups.

Minerals contained in the supply water will not freeze and are drained away.  Mostly pure water will be
frozen into the ice cubes.

During the freezing cycle, the compressor, fan motor, and water pump are operating.  Water is continuously
freezing or being sprayed and recirculated.  When the evaporator temperature is lowered to the cold
temperature setting of the cube size control, it ends the freezing cycle and starts the harvest cycle.

 

Harvest Cycle

The hot gas valve opens and hot refrigerant gas is discharged into the evaporator.  The inlet opens and a
fresh supply of water flows to the top of the evaporator and then drains into the reservoir.

The ice cubes have been released from the inverted cube cups in the evaporator by the warming effect of
the hot refrigerant gas condensing in the evaporator tubing, plus the incoming water flowing around the
inverted cups.  The released ice cubes drop onto the spray platform and through the curtain assembly into
the ice storage bin.

 

The cube size control thermostat senses the
warmer temperatures of the harvest cycle, and
at a preset temperature, opens the circuit to
the hot gas and inlet water valves.  Both valves
then close.

The harvest cycle is complete, and the
freezing cycle restarts.

The automatic ice making process continues
until the bin is full of ice, and the bin thermostat
senses a colder temperature.

The bin thermostat then opens the circuit to all
components and the automatic ice making
process stops.

Содержание ICEU060

Страница 1: ...Mile High Equipment 11100 East 45th Ave Denver Colorado 80239 Part Number 9081291 01 Print Date 11 01 MODEL ICEU060 ICE UNDERCOUNTER SERIES CUBERS SERVICE AND INSTALLATION MANUAL...

Страница 2: ...Works Water System Page 9 How It Works Refrigeration Page 10 11 Operation And Adjustment Page 12 Sanitizing And Cleaning Page 13 Service Diagnosis Page 14 Component Replacement Page 15 16 Wiring Diag...

Страница 3: ...or installations Machine requires voltage indicated on rating nameplate Failures caused by improper voltage are not considered factory defects Extended periods of operation at temperatures exceeding l...

Страница 4: ...lity connections Allow enough space for the machine to be pulled out from its installed location Do not build a floor in front of the machine that would prevent its removal Air Circulation The front p...

Страница 5: ...un is recommended Install the drains per local code A vent is recommended on the highest point of the drain tube and the drain tubing must be rigid pipe DO NOT use flexible tubing Electrical 1 Locate...

Страница 6: ...cuit 5 Is the water supply line shut off valve installed and is the water turned on 6 Have the bin interior and cabinet exterior been wiped clean 7 Are all internal components in place including spray...

Страница 7: ...uns this is normal 9 After about 20 minutes the machine will begin to release ice This is called the harvest cycle Observe the first cube harvest a Check the size of the ice cubes Note The normal size...

Страница 8: ...tat control body is located in front of the control box just beside the cube size control The thermostat sensing tube is located in the ice storage bin on the left side wall and will automatically shu...

Страница 9: ...Component Location ICEU060 Page 8...

Страница 10: ...ns and hot refrigerant gas is discharged into the evaporator The inlet opens and a fresh supply of water flows to the top of the evaporator and then drains into the reservoir The ice cubes have been r...

Страница 11: ...the condenser The refrigerant then condenses into a high pressure liquid From the condenser the liquid refrigerant flows through the liquid line and the liquid line filter drier After the filter drie...

Страница 12: ...strainer outlet is connected to two tubes one which leads to a hot gas valve solenoid When this valve opens the refrigerant gas follows the path of least resistance and flows through the tubing from t...

Страница 13: ...llustration at the right 1 Remove the front panel locate knob 2 To increase the cube size turn knob 1 8 turn clockwise To decrease the cube size turn the knob 1 8 turn counter clockwise 3 Observe the...

Страница 14: ...ce produced during cleaning and to clean out the drain Wipe the interior of the bin with mild soap and hot water rinse with cold water To sanitize prepare ounce of approved EPA FDA sodium hypochloride...

Страница 15: ...jets Some cloudy Shortage of water Check water supply Cubes too large Cube size control adjusted Check and adjust for proper operation improperly Decreased ice capacity Inefficient compressor Replace...

Страница 16: ...rews and control box cover to gain access to the cube size control body Remove screws and dismount the cube size control from the control box Disconnect the electrical wires from the cube size control...

Страница 17: ...er valve 4 Disconnect electrical wires from the inlet water valve 5 Disconnect water lines to and from the water valve 6 Remove the valve from the icemaker 7 Reverse removal procedure to replace Water...

Страница 18: ...Component Layout ICEU060 Page 17...

Страница 19: ...Wiring Diagram ICEU060 Page 18...