GEM Models A/W
For the Installer
Page
1
Installation Guidelines:
For proper operation of the Ice-O-Matic ice machine, the following installation guidelines must be followed.
Failure to do so may result in loss of production capacity, premature part failures, and may void all warranties.
Ambient Operating Temperatures:
Minimum Operating Temperature: 50°F (10°C)
Maximum Operating Temperature 100°F (38°C)
Note: Ice-O-Matic ice makers and dispensers are not approved for outdoor installation.
Incoming Water Supply
Minimum incoming water temperature: 40°F (4.5°C)
Maximum incoming water temperature: 100°F (38°C)
Minimum incoming water pressure: 20 psi (1.4 bar)
Maximum incoming water pressure: 80 psi (4.1 bar)
Note: If water pressure exceeds 80 psi a water pressure regulator must be installed.
Drains
All drain lines must be installed per local codes. Flexible tubing is not recommended. Route bin drain, vented
float overflow drain and water condenser drain individually to a floor drain.
The use of condensate pumps for
draining water is not recommended by Ice-O-Matic. Ice-O-Matic assumes no responsibility for improperly
installed equipment.
Water Filtration
A water filter system should be installed with the ice machine.
Clearance Requirements
Self-contained air cooled ice machines must have a minimum of 6 inches (15cm) of clearance at the rear and
sides of the ice machine for proper air circulation.
Stacking
Ice-O-Matic Pearl Ice™ machines are not designed to be stacked.
Dispenser Application
The Pearl Ice™ machine is approved for specific dispenser applications, reference page 4.
Electrical Specifications
Refer to the serial plate at the rear of the ice machine to make sure proper voltage and circuit breaker size
have been supplied. Make sure the machine is on a dedicated circuit. The Pearl Ice™ Series are not supplied
with an electrical power cord and will need to be installed and wired per local electrical codes.
Adjustments
Level the machine within 1/8 inch in all directions. Adjust the cabinet or bin legs as required.
Check the bin control for proper operation.
Check the water level in the reservoir for proper adjustment.
Check the water regulating valve adjustment if water cooled.
Caution:
Electrical connection must be made or a cord installed by a qualified electrician or there is danger of
an electrical fire.
Содержание GEM1856
Страница 2: ......
Страница 8: ...GEM Models A W For The Installer Page 2 GEM0650 0655 0956 0955 A W ...
Страница 9: ...GEM Models A W For The Installer Page 3 GEM1256A W ...
Страница 40: ...GEM Models A W Wiring Diagram Page 34 Wiring Diagram GEM0650 A W ...
Страница 41: ...GEM Models A W Wiring Diagram Page 35 Wiring Diagram GEM0956 A W GEM1256A W ...
Страница 42: ...GEM Models A W Wiring Diagram Page 36 Wiring Diagram GEM0655 A W GEM0955 A W ...
Страница 43: ...GEM Models A W Wiring Diagram Page 37 Wiring Diagram GEM1856 Air ...
Страница 44: ...GEM Models A W Wiring Diagram Page 38 Wiring Diagram GEM1855 Air ...