Troubleshooting

IMPORTANT: It is not the intent of this maintenance manual to 
resolve any problems with the operation of your Ice Air unit. 
Please contact a trained servicer or building maintenance 
staff immediately if your unit fails to perform properly.

1.  Contact a trained service technician to conduct full unit 

diagnostics and repair to equipment. 

2.  Record any unit that does not operate noting the unit serial 

number on your report.

If unit is not operating, conduct the following checks:

1.  Check the electrical connections.
2.  Check the voltage and current against the electrical 

specifications on the unit nameplate.

3.  Look for wiring errors. Check for loose screw connections in both 

line and low voltage terminals.

4.  Check the water supply piping for proper water connection.
5.  Check for dirty filters.
6.  Check indoor fan for proper operation.
7.  Check that unit did not cycle off due to improper thermostat 

settings.

8.  Check for fault codes on the control board – consult the Board 

Troubleshooting Table.

p

 

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

p

!

  

WARNING: 

Ice Air will not be responsible for any injury or 

property damage arising from improper service or service 
procedures. If you install or perform service on this unit, you 
assume responsibility for any personal injury or property 
damage which may result. Many jurisdictions require a license 
to install or service heating and air conditioning equipment.

p

!

  

WARNING HIGH VOLTAGE:

 

Disconnect all power before 

servicing or installing unit. Multiple power sources may be 
present. Failure to do so may cause property damage,  
personal injury or death.

Содержание FCHR

Страница 1: ...FCHR Hi Rise Unit Fan Coil Unit FCU ELA 8842 Operating and Maintenance Manual...

Страница 2: ...tained in this Operating and Maintenance Manual We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual and to the various safety advi...

Страница 3: ...Our Ice Air units must each be wired on an individual dedicated electrical circuit with the correct voltage and proper amperage capacity to match the unit nameplate requirements Each unit s electrical...

Страница 4: ...ing product development programs the information in this document is subject to change without notice 4 Components and Parts View 3 88 12 17 1 8 SURFACE MOUNT CONTROL OPTIONAL ACCESS PANEL RISER SUPPL...

Страница 5: ...Total Elec Heat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO...

Страница 6: ...nless Steel X None Item 16 A Flow Regulation Cooling Coil A Balancing Valve B Circuit Setter C Autoflow Valve 0 5 GPM D Autoflow Valve 1 0 GPM E Autoflow Valve 1 3 GPM F Autoflow Valve 1 5 GPM G Autof...

Страница 7: ...grams for highest efficiency Factory or field set temperature limits Large clear display in any lighting condition Auto changeover mode Easy to program Wireless Thermostat Optional Easy programming Se...

Страница 8: ...on Press Hold UP Override mode UP Permanent Override mode DOWN Override mode DOWN Permanent Override mode ON OFF ON OFF MODE Set operation mode Internal Setting FAN Set fan speed Confirm The temperatu...

Страница 9: ...oint 2 In Heat mode Heat set point can be adjusted 3 In Cool mode Cool set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the Heat set point Press FA...

Страница 10: ...mode and inlet water temperature is below 85 F the Auto Seasonal Changeover switch shall open the valve and allow cool water to circulate through the system else the valve remains shut to prevent hot...

Страница 11: ...your model Indoor Air Filter All units are equipped with either a reusable filter shown abve or a single dispensible filter The reusable filter is washable and it is recommended you clean the filter a...

Страница 12: ...mplemented by trained personnel But there are certain items that you the apartment owner or tenant can do to ensure proper unit function Keep the area in front of your unit clear of objects that may b...

Страница 13: ...e and current against the electrical specifications on the unit nameplate 3 Look for wiring errors Check for loose screw connections in both line and low voltage terminals 4 Check the water supply pip...

Страница 14: ...r equipment improperly returned as defective and or as being in warranty To obtain assistance under the parts warranty or to purchase the optional extended warranty simply contact Ice Air Customer Ser...

Отзывы: