VIII. TROUBLE SHOOTING / 

PETUNJUK KETIDAKNORMALAN

 

 

SYSTEM 

PROBLEM CAUSE 

RECOMMENDED SOLUTION 

“Line On” indicator not light.

 

1.

 

Main  voltage  <

 

170Vac  or

      

> 255Vac . 

2.   Problem in transfer switch control. 

1.  Check your mains voltage. 
2.  If main voltage > 170Vac and < 255Vac, 

call for service. 

Main  voltage  <  170Vac,  turn  on 
main  switch,  battery  low light  on 
after  ±  5  seconds  go  out,  but 
inverter does not work.

 

Battery voltage low. 

1.  Check battery voltage. 
2.  Charger  battery  ±  10  hour  by  kept  the 

main  switch  in  on  position  when  AC 
mains normal. 

3.  Call for service. 

When AC main failure and inverter 
does not work. 

1.

 

Battery fuse broken

2.

 

Problem in inverter circuit

1.  Check battery fuse and replace  with the 

same rating. 

2.  If the fuse blown again, call for service. 

Communication 

from 

UPS 

to 

computer fail.

 

1.

 

Interface cable not connected

.  

2.

 

Interface cable wrong or broken

3.

 

Software has not been installed

 

or configure properly.

 

 

1.  Install the interface cable. 
2.  See software manual. 
3.  If  the  problem  still  occur,  call  for 

service. 

 

 

 

 

 

 

 

 

 

Содержание ST 1023B

Страница 1: ...481 1180070 121 ST 1023 B ICA UNINTERRUPTIBLE POWER SYSTEMS ST 623 B Rev 01 ...

Страница 2: ...I TEKNIK 2 III FRONT PANEL REAR PANEL VIEW TAMPAK PANEL DEPAN PANEL BELAKANG 3 IV START UP UPS MENGHIDUPKAN UPS 4 V OPERATION PROCEDURE CARA MENGOPERASIKAN 5 VI UPS INSTALLATION PEMASANGAN UPS 5 VII TABLE OF INDICATOR STATUS TABEL STATUS INDIKATOR 6 VIII TROUBLE SHOOTING PETUNJUK KETIDAKNORMALAN 7 ...

Страница 3: ...m UPS to Computer is power fail and battery low AC INPUT TO COMPUTER UPS OUTPUT TRANSFER SWITCH INVERTER CHARGER BATTERY STABILIZER INDICATOR CONTROLCIRCUIT UPS Uninterruptible Power Supplies dapat melindungi peralatan Anda yang rentan terhadap gangguan kelistrikan seperti komputer instrument terkomputerisasi PABX faksimili cash register dan peralatan elektronik lainnya UPS ini terdiri atas invert...

Страница 4: ...otection Fuse Topology Constant Voltage CHG Floating Voltage V 27 0 40 5 Wave Form Sinewave Distortion 3 THD Load 0 100 Topology Pulse Width Modulation PWM Voltage V 220 2 Frequency Hz 50 1 INV O U T Efficiency 80 At Full Load Transfer Time ms 4 Back Up Time min 10 At Nominal Load AC Input Low Fail Every 4 seconds AC Input High Every 1 second BUZ ZER Battery Low Every 1 second Operation Temperatur...

Страница 5: ...unjukkan keadaan beban lebih 6 Inverter Test Test Inverter To inverter test when line power on Untuk melakukan test inverter saat AC input ada 7 RS232 Connector Konektor RS232 For communication between UPS and computer Untuk komunikasi antara UPS dengan komputer 8 Outlet Stopkontak Keluaran 9 Inlet Stopkontak Masukan 10 Jack RJ11 Internet modem protection Perlindungan modem internet Notice Please ...

Страница 6: ...eban yang terpasang pada stopkontak keluaran 2 Hubungkan steker kabel daya ke stopkontak jala jala yang mempunyai arde 3 Hidupkan UPS dengan menekan tombol daya Led merah TEGANGAN BATERAI RENDAH akan menyala sekitar 2 detik dan padam kembali bila kondisi baterai baik Bersamaan dengan itu led hijau LISTRIK JALA JALA menyala bila tegangannya 170V dan 255V yang menunjukkan keluaran UPS berasal dari l...

Страница 7: ...jala terganggu padam atau tegangannya terlalu rendah tinggi inverter langsung bekerja dengan waktu alih 4 ms mengubah daya baterai menjadi arus listrik AC Buzzer akan berbunyi putus putus selang 4 detik jika listrik jala jala mati atau 170V dan selang 1 detik jika listrik jala jala 255V Saat baterai hampir habis buzzer akan berbunyi sinambung Pada saat ini data harus sudah tersimpan dan semua beba...

Страница 8: ... 0 Check the utility power 260 Vac Inverter is on at low battery voltage 1 0 0 1 0 1 1 0 Save your work now the inverter will be cut off 1 Utility power is normal 2 Overload 1 1 0 0 1 0 0 1 Remove some load from the UPS Remarks 1 On NP Audible alarm continuous sounds 0 Off NTPL Audible alarm sound every 4 seconds L1 Green Led Line On NTPC Audible alarm sound every 1 second L2 Yellow Led Inverter L...

Страница 9: ...e low 1 Check battery voltage 2 Charger battery 10 hour by kept the main switch in on position when AC mains normal 3 Call for service When AC main failure and inverter does not work 1 Battery fuse broken 2 Problem in inverter circuit 1 Check battery fuse and replace with the same rating 2 If the fuse blown again call for service Communication from UPS to computer fail 1 Interface cable not connec...

Страница 10: ...Telephone 6906020 Hunting SERVICE CENTRE ICA Jln Pinangsia Raya I No 22BB Jakarta Barat ...

Отзывы: