ICA Duster 3000 Скачать руководство пользователя страница 3

Warnings Before Use:  

x

  The operation of this unit does not exclude the proper use of industry approved 

respirators and Island Clean Air Inc. cannot guarantee health benefits. 

x

  This machine is not to be used in hazardous locations, where explosive, 

combustible, corrosive, or conductive dust, vapors, or gases are present.  

x

  Use of the Duster 3000 without filters or with non-ICA branded filters will void 

the warranty. 

 

Duster 3000 Setup Step 1: Uncrate the Duster 3000 

x

  Remove all 

WKHVFUHZVIURPWKHIURQWWZR´[´ZRRGHQVXSSRUWXSULJKWVDQG

front wooden panels with a #2 Philips screwdriver or power tool. 

x

 

5HPRYHWKHWZR´[´ZRRGHQVXSSRUWXSULJKWV

x

  Roll the Duster 3000 off the skid. 

x

  Remove the plastic bag. 

 

Duster 3000 Setup Step 2: Install the Intake Filters 

x

  Remove the three intake filters from their boxes. 

x

  Insert the intake filters in front of the preinstalled carbon filters. Make sure that 

the black Velcro pull tabs attached to the carbon filters are not pinched 
between the filters. 

x

  Secure the intake filters with the Velcro tabs located on both sides of each filter. 

 

 

Correct 

Incorrect 

x

  Proper sealing of the intake filters will prevent dirty air from bypassing the 

metal framed intake filters. Improper sealing will plug up the carbon filters and 
the top filter.    

 

Duster 3000 Setup Step 3: Plug in the Duster 3000 

x

  Locate an electrical outlet that is capable of handling the Duster 3000: 

x

  110-120Vac, 12A, 60Hz, 1Ph 

x

  If connected to a circuit 

SURWHFWHGE\$IXVHVXVHGHOD\IXVHVPDUNHG³'´

 

x

  Make sure your electrical power panel is capable of handling a 12A load in 

addition to your current usage. Overloading your panel may not allow the 
Duster 3000 to function correctly or to its full airflow capacity. 

x

  Roll the Duster 3000 into position, plug it in, and turn it on. 

 

 

Содержание Duster 3000

Страница 1: ...Duster 3000 Operations Maintenance Manual ...

Страница 2: ...ess represent a dramatic breakthrough in the application of modern air cleaning technology The instructions on the following pages will walk you through the setup and operation of the Duster 3000 Parts Diagram Parts List 1 Housing Assembly 2 Lexan Top Filter Shroud 3 Power Cord 4 Motor 5 Blower 6 On Off Power Switch 7 2 Light Indicator Panel 8 Digital Airflow Gauge 9 Quick Release Latches 10 Rubbe...

Страница 3: ...ers from their boxes x Insert the intake filters in front of the preinstalled carbon filters Make sure that the black Velcro pull tabs attached to the carbon filters are not pinched between the filters x Secure the intake filters with the Velcro tabs located on both sides of each filter Correct Incorrect x Proper sealing of the intake filters will prevent dirty air from bypassing the metal framed ...

Страница 4: ... trap particles the CFM will drop x The green light indicates that the machine is on and is in good working order x The yellow light indicates that the filters are dirty and need cleaning or replacing x The Duster 3000 will automatically shut down when the yellow light comes on to prevent permanent damage to the motor x The yellow light has been factory preset to go off around 2300 CFM or lower ...

Страница 5: ...00 has three sets of filters around the base of the unit These perform the majority of the air filtration and require routine maintenance Green Pre Filter Pad Part 11703 x Filters dust and large particles x Clean daily or weekly x Clean by vacuuming the front of the green pad Remove from intake filter and blow out with compressed air Do not pressure wash Pleated Intake Filter Part 11204 x Filters ...

Страница 6: ...1 x Absorbs VOCs fumes and odors x Not cleanable x Replace when it weighs over 47lbs Top Filter Replacement 1 Open the four latches located on the sides of the Duster 3000 2 Lift and remove the Lexan top filter shroud 3 Lift and remove the old top filter and replace with new top filter 4 Reinstall Lexan top filter shroud 5 Close the four latches General Maintenance x Once a year we recommend a gen...

Страница 7: ...ard must be completed and returned to ICA All products made by ICA are warranted to be free of defects in materials and workmanship for a period of one 1 year from the date of original purchase This limited warranty does not include filters cleaning or damages caused by neglect or misuse and will cease if the product is resold rented or otherwise disposed of Only factory original filters are recom...

Страница 8: ... Business Park Vancouver BC V5X 4N6 Canada Tel 604 322 D 8674 PDLO LQIR LVODQGFOHDQDLU FRP HEVLWH www islandcleanair com Committed to Green ATEX Approved CSA Certified Air Resources Board Printed in Canada Specifications subject to change without notice May 2020 ...

Отзывы: