1
5
TOUR SETTING: Move the cursor to TOUR setting item and then click confirm button. You can see
the following interface. Here you can add or remove the preset, and set the corresponding dwell
time and call speed.
Figure 3-25 Tour setting-2
DWELL: Here is t set dwell time. Please use the left/right button on the keyboard or in the
speed dome terminal menu to set.
SPEED: Here you can set the speed value.
When you move the cursor to one tour number, you can use left/right button to turn the page.
When you move the cursor to one tour number, please click confirm button to set the tour. Please use
up/down button to set preset number, dwell time and speed. Use the left/right button to go to the next
tour. Click confirm button you can exit the setup. After you completed the setup, move the cursor to back
button to go to the previous interface.
DELETE TOUR
:
Here is to delete a tour. Input tour number in TOUR NO and then move the cursor
to DELETE TOUR, click confirm button to delete.
CALL: Here is to activate tour. Input tour number in tour NO and highlight CALL, click confirm button
to activate tour.
STOP: Here is to terminate touring.
BACK: Go back to previous menu.
EXIT: Log out system menu.
3.4.4.5
Pattern
Figure 3-26 Pattern setting
Pattern function can memory PTZ operation and camera focus zoom in and zoom out.
From the start position, dome begins auto movement repeatedly.
This series IP dome supports maximum 5 patterns and one pattern can max support 400 commands.
Move the cursor to PATTERN and click confirm button.
PATTERN NO
:
Here is to set pattern number. Please click left/right key to configure.
PROGRAM START: Here is to memorize pattern starting point. An icon OK pops up in screen to
prompt you system begins memory pattern.
PROGRAM STOP
:
Here is to set pattern stop point. After all the movement, move the cursor to
PROGRAM STOP and then click confirm button. Now you have set one pattern. System pops up an
icon OK to prompt you system has memories one pattern.
PATTERN NO
:
1
PROGRAM START
PROGRAM STOP
CALL
STOP
BACK
EXIT
NO PRESET DWELL
SPEED
01 000
005
013
02 000
005
013
03 000
005
013
…
…
…
…
32 000
005
013
BACK EXIT