12
The pump should be connected to the floor with the fittings provided.
PUMP OPERATING:
The pump works automatically. After filling up the pump chamber
with 6 litres of sewage the device will turn on automatically. After
pumping out the device will also turn off automatically. The work
cycle last around 8 seconds.
Thanks to the independent switch,
pump can be empted any time.
ELECTRICAL INSTALATION:
The pump needs a grounded power supply 230V/50Hz.
!
The pump plug must be plugged in to the grounded socket. The
manufacturer and guarantor do take any responsibility for the damage
done to people or things caused by the lack of the proper
grounding.
The yellow and green conductor of the connection cord
is grounding.
!
The power network supplying the pump should have protection switch
e.g. M611 protecting the engine from overloading. To work properly
the protective switch should be set up to the maximum power winding