4
SPECIFICATIONS
Power supply
1 x 220-240V~, 50 HZ.,5 Amp Circuit
Average utilization temperature
77°F(25°C)
Maximum allowable temperature S3 15% (90s ON, 510s OFF) 122°F(50°C)
Discharge
3/8 in. hose barb
Operation
NOTE: This unit is non-submersible. The pump should not be installed in a manner that will subject it to flooding, splashing or
spraying.
1
Mounting the pump
2
Connecting the air
conditioning condensate
drain tubing
The tank has two slots (1) provided to mount the
unit. The slots are located on the back of the tank.
Mount the unit either on the side of the air
conditioner unit or nearby wall.
The pump must be level and the inlet must be
below the coil drain. Conduit fittings are not
compatible with the plastic pump housing.
Ensure the tubing to the pump intake is fastened
securely so that it cannot come out of the pump
intake port.
Cut the tubing at an angle so that the bottom of the
reservoir does not close the tubing outlet. Be sure
the tubing does not interfere with the float.
3
Connecting the tubing
4
Plugging in the pump
Connect the tubing from the pump discharge hose
barb to the floor drain, laundry tub, or sink. Leave
an air gap above the tub drain.
Plug the pump power cord into a 230 volt properly
grounded power outlet.