RECOMMENDED  SETTINGS  FOR  DIFFERENT  CENTRAL  HEATING 
SYSTEMS:  
1) 

If a house has a two-pipe 
heating  system,  where 
one pipe is a supply pipe 
to  all  the  radiators  in  a 
loop  and  the  second 
parallel  pipe  is  used  to 
receive  the  cooled  water 

from the radiators, the most economic solution is to select the AUTO function. 
This type of installation also permits the selection of a higher setting from PP

alternating pressure.  
2)  

 
If a house has a one-pipe 
heating  system,  where 
the  cooled  water  from  a 
radiator  enters  a  pipe 
supplying  hot  water  to 
the  next  radiator  and 

Содержание BETA 25-60

Страница 1: ...s made by the user relating to the equipment s failure resulting from its inappropriate use CAUTION Non observance of recommendations listed in this operating manual may result in personal injuries or damage to units where the equipment is installed the environment or the pump itself CAUTION Children and persons with reduced physical sensory or mental capabilities must not use this equipment also ...

Страница 2: ...igned to pump substances which are corrosive flammable or have damaging or explosive properties for example petrol nitro petroleum etc as well as foodstuffs and salt water Equipment failures caused by this type of damage are not covered by the product s warranty The maximum temperature of pumped water is 110o C The pump is not adapted to pump water with an excessive level of mineral particles as t...

Страница 3: ... mechanical impurities into the pipework The pipework should be flushed through prior to the installation of the pump The pump should be installed with its shaft in a horizontal position The pump s ports can be in different positions to the ones shown in the picture below however the shaft of the pump must always be in a horizontal position If the pump is installed with its shaft in a vertical pos...

Страница 4: ...CAL CONNECTION The pump s power supply network should satisfy the requirements listed on the rating plate The pump has a cable with a plug which can be inserted into an earthed socket The pump needs to be connected to a network with an active earthing system The manufacturer and the guarantor will bear no responsibility for injuries to people or any damage caused by the lack of an appropriate eart...

Страница 5: ...d from the electrical network it should be unblocked failure repaired and switched on again Switching it off and then switching it back on again will reset the error message OPERATING MODE The subsequent pressing of the operating mode switch allows the user to select one of the eight settings The selected setting will be displayed by the operating mode display The pump s operating parameters are s...

Страница 6: ...second parallel pipe is used to receive the cooled water from the radiators the most economic solution is to select the AUTO function This type of installation also permits the selection of a higher setting from PP1 alternating pressure 2 If a house has a one pipe heating system where the cooled water from a radiator enters a pipe supplying hot water to the next radiator and ...

Страница 7: ...riod of approx 2 hours the pump will automatically start operating in night mode If the temperature of the heating medium increases by approx 10O C the pump will automatically return to the standard operating mode The night mode setting will not work if the pump is running in one of its constant speeds Disconnecting the electricity supply will deactivate the night mode Once the power supply is rec...

Страница 8: ...he maximum temperature of the heating medium is 110O C With the ambient temperature of 40O C the maximum temperature of the heating medium is 70O C With the ambient temperature of 35O C the maximum temperature of the heating medium is 90O C Any equipment damage caused by water vapour condensation is not covered by a warranty The surface temperature of the pump must not exceed 120O C Any equipment ...

Страница 9: ...eating medium to the installation The inlet pressure is too low Check the air quantity in the expansion vessel The pump is noisy there is noise in the installation The panel displays a number The pump performance is too high Decrease the pressure on the suction side The pump is running but provides insufficient heat The panel displays a number The pump operating parameters are too low Increase the...

Отзывы: