Parameters:
Name
Type
Description
Mandatory
Default
vol
Object name
The name of the
volume to be
resized.
Y
N/A
size
N/A
The new volume
size.
N
N/A
size_
blocks
N/A
New size of
volumes in
number of blocks.
N
N/A
shrink_
volume
Boolean
Must be specified
as
yes
if the new
size is smaller than
the current size.
N
No
force_on_
inactive_
mirror
Boolean
The parameter is
required for a
successful resize of
a volume if (1) the
volume is
mirrored, (2) the
volume is a
Master, and (3) the
mirror has been
deactivated by the
system following a
previously issued
resize command
that failed to
successfully
complete due to a
communication
error.
N
No
This command resizes a volume.
The volume can be resized in either direction. However, whenever the volume is
downsized, you have to specify this with shrink_volume="yes".
The new size of the volume is specified as an integer multiple of 10
9
bytes, but the
actual new size of the volume is rounded up to the nearest valid size, which is an
integer multiple of 16 x 2
30
bytes.
If the new size equals the current size, the command will succeed without changes
to the volume.
The volume's address space is extended at its end to reflect the increased size, and
the additional capacity is logically formatted (that is, zeros are returned for all read
commands).
When resizing a regular volume (not a writable snapshot), all storage space that is
needed to support the additional volume's capacity is reserved (static allocation).
This guarantees the functionality and integrity of the volume, regardless of the
resource levels of the volume's Storage Pool. The command fails if this reservation
cannot be committed.
The volume's lock state must be unlocked when the command is issued, or
otherwise the command fails.
v
Resizing a master volume does not change the size of its associated snapshots.
Chapter 3. Volume Management
55
Содержание XIV STORAGE SYSTEM
Страница 1: ...Version 11 4 x IBM XIV Storage System User Manual GC27 3914 05...
Страница 10: ...4 IBM XIV Storage System User Manual...
Страница 42: ...36 IBM XIV Storage System User Manual...
Страница 66: ...60 IBM XIV Storage System User Manual...
Страница 68: ...62 IBM XIV Storage System User Manual...
Страница 82: ...76 IBM XIV Storage System User Manual...
Страница 106: ...100 IBM XIV Storage System User Manual...
Страница 124: ...118 IBM XIV Storage System User Manual...
Страница 140: ...134 IBM XIV Storage System User Manual...
Страница 180: ...174 IBM XIV Storage System User Manual...
Страница 202: ...196 IBM XIV Storage System User Manual...
Страница 264: ...258 IBM XIV Storage System User Manual...
Страница 352: ...346 IBM XIV Storage System User Manual...
Страница 405: ...User Category Permission Technicians Allowed Chapter 19 Fibre Channel and iSCSI Configuration and Status 399...
Страница 406: ...400 IBM XIV Storage System User Manual...
Страница 476: ...470 IBM XIV Storage System User Manual...
Страница 486: ...480 IBM XIV Storage System User Manual...
Страница 640: ...634 IBM XIV Storage System User Manual...
Страница 642: ...636 IBM XIV Storage System User Manual...
Страница 651: ......
Страница 652: ...Printed in USA GC27 3914 05...