284
IBM eX5 Implementation Guide
Figure 6-68 IMM System Health Summary
14.Power on the x3850 X5.
15.At the UEFI panel, press F1 for the UEFI menu.
16.Select System Settings
Memory and change the MAX5 Memory Scaling Affinity to
Non-Pooled, as shown in Figure 6-69.
Figure 6-69 UEFI setting for MAX5 Memory Scaling Affinity
17.Press Esc two times to go back to the Main page. Select Save Settings and press Enter
to save the UEFI settings.
18.Exit the UEFI and boot the system to ESX.
Figure 6-70 ESX 4.1 Installable NUMA error
If you see this error, follow these steps to change the boot code:
1. At the VMware bootloader panel, press a to modify the kernel arguments. Be sure that
VMware ESX 4.1 is highlighted, as shown in Figure 6-71 on page 285.
Important: If you do not select VMkernel.Boot.allowInterleavedNUMAnodes under
VMkernel, Figure 6-70 shows the error that will appear during boot.
Содержание x3850 X5
Страница 2: ......
Страница 3: ...International Technical Support Organization IBM eX5 Implementation Guide May 2011 SG24 7909 00...
Страница 20: ...xviii IBM eX5 Implementation Guide...
Страница 32: ...12 IBM eX5 Implementation Guide...
Страница 34: ...14 IBM eX5 Implementation Guide...
Страница 74: ...54 IBM eX5 Implementation Guide...
Страница 136: ...116 IBM eX5 Implementation Guide...
Страница 238: ...218 IBM eX5 Implementation Guide...
Страница 392: ...372 IBM eX5 Implementation Guide...
Страница 466: ...446 IBM eX5 Implementation Guide...
Страница 484: ...464 IBM eX5 Implementation Guide Figure 9 14 IMM Remote Control Video Viewer showing power control options...
Страница 560: ...540 IBM eX5 Implementation Guide...
Страница 564: ...544 IBM eX5 Implementation Guide...
Страница 578: ...IBM eX5 Implementation Guide IBM eX5 Implementation Guide...
Страница 579: ......