146
IBM eX5 Implementation Guide
Table 4-17 x3690 X5 hard drive backplanes
As listed in Table 4-17, the backplane option part numbers include the necessary cables to
connect the backplane to the SAS controller. The
short
SAS cable is needed when installing a
hard drive backplane for 2.5-inch bays 1 - 8 (the left half of the drive bays in the server, when
looking from the front). The
long
SAS cable is used for hard drive backplanes for 2.5-inch
bays 9 - 16 (the right half of the drive bays, when looking from the front).
When configuring an order by using feature codes, for example, with configure-to-order
(CTO), the feature codes for the backplanes do not include the cables. You must order the
cables separately, as listed in Table 4-18.
Table 4-18 x3690 X5 SAS cable options (not needed if ordering backplane part numbers)
Part
number
Feature
code
Backplane
Drives supported
SAS cables
included
a
a. See the next paragraph for a description of short and long cables. The option part numbers include the cables.
If you order a configuration by using feature codes, use Table 4-18.
60Y0339
9287
IBM 4x 2.5” HS SAS HDD Backplane
Four 2.5” SAS drives
1 short, 1 long
60Y0381
1790
IBM 8x 2.5” HS SAS HDD Backplane
Eight 2.5” SAS drives
2 short, 2 long
Part number
Feature code
Description When
used
69Y2322
6428
x3690 X5 short SAS cable
For backplanes of bays 1 - 8
69Y2323
6429
x3690 X5 long SAS cable
For backplanes of bays 9 - 16
Using the ServeRAID Expansion Adapter: When using this adapter, the adapter must be
installed in PCIe slot 1. Short SAS cables are used to connect the two ports of the
ServeRAID controller to the two controller I/O ports on the expander. All four backplane
SAS cable connections are connected to the ServeRAID Expander using the long SAS
cables that are shown in Table 4-18 on page 146.
Содержание x3850 X5
Страница 2: ......
Страница 3: ...International Technical Support Organization IBM eX5 Implementation Guide May 2011 SG24 7909 00...
Страница 20: ...xviii IBM eX5 Implementation Guide...
Страница 32: ...12 IBM eX5 Implementation Guide...
Страница 34: ...14 IBM eX5 Implementation Guide...
Страница 74: ...54 IBM eX5 Implementation Guide...
Страница 136: ...116 IBM eX5 Implementation Guide...
Страница 238: ...218 IBM eX5 Implementation Guide...
Страница 392: ...372 IBM eX5 Implementation Guide...
Страница 466: ...446 IBM eX5 Implementation Guide...
Страница 484: ...464 IBM eX5 Implementation Guide Figure 9 14 IMM Remote Control Video Viewer showing power control options...
Страница 560: ...540 IBM eX5 Implementation Guide...
Страница 564: ...544 IBM eX5 Implementation Guide...
Страница 578: ...IBM eX5 Implementation Guide IBM eX5 Implementation Guide...
Страница 579: ......