b. Update the UEFI code, following the instructions that come with the update
file that you downloaded.
2. Update the IMM firmware:
a. Download the latest version of the IMM firmware from http://www.ibm.com/
b. Update the IMM firmware, following the instructions that come with the
update file that you downloaded.
3. Configure the UEFI settings:
a. When you are prompted to start the Configuration/Setup Utility program,
restart the server and press F1.
b. Select
System Settings
→
Devices and I/O Ports
.
c. Select
Console Redirection Settings
; then, make sure that the values are
set as follows:
v
COM Port 1
: Enable
v
Remote Console
: Enable
v
Serial Port Sharing
: Enable
v
Serial Port Access Mode
: Dedicated COM1 Settings
v
Baud Rate
: 115200
v
Data Bits
: 8
v
Parity
: None Stop
v
Bits
: 1
v
Thermal Emulation
: ANSI
v
Active After Boot
: Enable
v
Flow Control
: Hardware
d. Press Esc twice to exit the
Devices and I/O Ports
section of the
Configuration/Setup Utility program.
e. Select
Save Settings
; then, press Enter.
f. Press Enter to confirm.
g. Select
Exit Setup
; then, press Enter.
h. Make sure that Yes, exit the Setup Utility is selected; then, press Enter.
Using the LSI Logic Configuration Utility program
Use the information in this section to configure an optional LSI RAID controller. If
you need to configure an optional ServeRAID controller, see “Configuring a
ServeRAID controller” on page 249. You can also select
System Settings
and
Adapters and UEFI Drivers
on the Setup utility to view a list of UEFI device
drivers that support configuration; then, select the adapter that you want to
configure to start a configuration program (see “Using the Setup utility” on page
235).
Use the LSI Logic Configuration Utility program to configure and manage redundant
array of independent disks (RAID) arrays. Be sure to use the program as described
in this document. Use the LSI Logic Configuration Utility program to perform the
following tasks:
v
Perform a low-level format of a hard disk drive
v
View or change IDs for attached devices
v
Set device scan order
v
Set protocol parameters on hard disk drives
Chapter 6. Configuration information and instructions
247
Содержание x3630 M3 7377
Страница 1: ...IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 40: ...22 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 142: ...124 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 250: ...232 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 286: ...Taiwan Class A compliance statement 268 IBM System x3630 M3 Type 7377 Problem Determination and Service Guide ...
Страница 293: ......
Страница 294: ... Part Number 00D3232 Printed in USA 1P P N 00D3232 ...