background image

IBM Asia Pacific Hardware Announcement AG11-0009

IBM is a registered trademark of International Business Machines Corporation

2

• 5U tower industry-standard models, rack mount special bid option
• Two USB front and four USB rear ports, one USB internal port, one com port, one

d-sub connector, three 10/100/1000 RJ45 ports, one serial port

Overview

The System x3500 M3 servers include:

• Quickpath Interconnect (QPI) support for 4.8, 5.86, and 6.4 Gigabit transfers/

second (GTS)

• Three hot-swap fans standard and three additional, with redundant power and

cooling optional

• Six PCI-Express card slots, and one PCI 32-bit/33 MHz card slot
• Integrated dual Gigabit Ethernet and standard RAID -0, -1, -10 (upgradeable), or

RAID 0, -1, -1E, -5, -50, with PCI-E adapter

• Optional RAID 6 or 60 via Advance Feature Key
• DDR3 ECC DIMMs, combined with an integrated ECC memory controller in core

logic that corrects many soft and hard single-bit memory errors and minimizes

disruption of service to LAN clients

• Integrated management module with Remote Presence function standard
• Light path diagnostics with a light path panel visible at front of chassis

Powered and scaled for business growth

• These servers contain one of the following

– A 2.13 GHz/4.8 GTS-8 MB 4C Intel E5606, a 2.26 GHz/4.80 GTS-8 MB 4C

E5607, a 2.4 GHz/5.86 GTS-12 MB 4C E5620, a 2.4 GHz/5.86 GTS- 12 MB 6C

E5645, a 2.53 GHz/5.86 GTS- 12 MB 6C E5649, a 2.66 GHz/6.4 GTS- 12 MB

6C X5650, a 3.06 GHz/6.4 GTS-12 MB 6C X5675, or a 3.46 GHz/6.4 GTS-12

MB 6C X5690 Intel Xeon processor data bus to the system.

– Data bus to the system delivering up to 10.6 Gb/s data transfer rate

• A 1333 MHz functional speed processor operations to memory and PCI bus
• 4 GB of high-speed, DDR3 - 1333 MHz ECC memory

1

, 192 GB maximum using 16

GB memory DIMMs

6

• High-speed, wide-bandwidth slots: Six PCI-E bus slots, and one PCI 32-bit/33

MHz bus slot

• Dual Broadcom 5709C Gigabit Ethernet ports and SAS/SATA support
• Standard SATA DVD-ROM and tape drive bay
• Eight standard SFF hot-swap drive bays and up to twenty-four 2.5-inch bays

available using upgrade options with total HDD storage capacity of 24 TB, using 1

TB Near-Line SFF SAS/SATA HDD options

High availability for around-the-clock business demands

• Integrated systems management processor and support for the Remote Presence

function

• Wake on LAN®
• ECC memory to detect double-bit errors and correct single-bit errors
• Integrated memory mirroring

Service and support perfected for business needs

• ServerGuide

TM

 and IBM® Director

• IBM Server support and web support 

3

• Three-year, customer replaceable unit (CRU) and on-site service

4

, limited

warranty

5

; optional warranty service upgrades available

Содержание x3500 M3 7380

Страница 1: ...0 M3 servers feature Powerful 4C 2 13 GHz 2 26 GHz and 2 4 GHz 2 53 GHz 6C 2 66 GHz 6C or 3 06 GHz 6C or 3 46 GHz 6C Intel Xeon processors with 8 MB or 12 MB cache model dependent 4 GB of 1333 MHz DDR...

Страница 2: ...C Intel E5606 a 2 26 GHz 4 80 GTS 8 MB 4C E5607 a 2 4 GHz 5 86 GTS 12 MB 4C E5620 a 2 4 GHz 5 86 GTS 12 MB 6C E5645 a 2 53 GHz 5 86 GTS 12 MB 6C E5649 a 2 66 GHz 6 4 GTS 12 MB 6C X5650 a 3 06 GHz 6 4...

Страница 3: ...with 12 slots populated with 16 GB DIMMs optional 4 GB memory standard Key prerequisites Monitor Planned availability date March 15 2011 System x3500 M3 7380 Description Related options IBM memory opt...

Страница 4: ...processors with Quickpath Interconnect QPI support SMP applications when installed in the second processor slot of all System x3500 M3 models with similar processors Note DDR3 ECC DIMMs combined with...

Страница 5: ...16 DIMM connectors supporting 1 GB 2 GB 4 GB 8 GB or 16 GB DDR3 1333 MHz SDRAMs memory for improved performance Up to 192 GB of system memory with 16 GB memory RDIMMs installed High speed wide bandwi...

Страница 6: ...cool system and enable replacement without powering down the server Integrated management module that supports Fan monitoring and control Power supply monitoring Temperature monitoring Voltage monito...

Страница 7: ...nitor Power good signal monitor System ID and planar version detection System power control System reset control NMI and SMI detection and generation System Interrupts Serial port text console redirec...

Страница 8: ...d and automatically increased to maintain system cooling if temperature thresholds are exceeded An alert is generated if Failure occurs or is predicted Installation or removal occurs Power supply cond...

Страница 9: ...t a computer system including hardware the operating system and application software This integration enables Windows to determine which applications are active and handles all of the power management...

Страница 10: ...ptional drive bays and a device bay for high capacity tape drives make these servers ideal for mainstream network computing Product number Part Description Number 2GB 1x2GB 1Rx8 1 35V PC3L 10600 CL9 E...

Страница 11: ...G2R 7380G2R G2V 7380G2V System x3500 M3 7380 H2A 7380H2A H2B 7380H2B H2E 7380H2E H2J 7380H2J H2K 7380H2K H2M 7380H2M H2Q 7380H2Q H2R 7380H2R H2V 7380H2V System x3500 M3 7380 44A 738044A 44B 738044B 4...

Страница 12: ...stallation and setup installing options reference information and problem determination The installation guide has easy to use text and pictorials to enable you to quickly set up the System x3500 M3 s...

Страница 13: ...BookManager READ licensed programs in any of the supported environments Terms and conditions for use of the machine readable files are shipped with the files Source file publications The product book...

Страница 14: ...mory PC3 10600 4 GB ECC 4 GB ECC 4 GB ECC 999 1 x 4 GB 1 x 4 GB 1 x 4 GB 2Gb 1Rx8 1 35V 2Gb 1Rx8 1 35V 2Gb 1Rx8 1 35V No ChipKill No ChipKill No ChipKill DIMM sockets 16 16 16 Capacity 192 GB 6 192 GB...

Страница 15: ...al PCI slots 7 7 7 PCI E slots 6 6 6 32 bit 33 MHz 1 1 1 Slots available 5 5 5 Integrated management Standard 11 Standard 11 Standard 11 Ethernet controllers 10 100 1000 Mb 10 100 1000 Mb 10 100 1000...

Страница 16: ...t provides a set of monitoring and alert features Refer to the Description section for details 12 The 920 watt redundant power supply is designed to support all systems SATA DVD drive characteristics...

Страница 17: ...t kilovolt amperes kVA approximately Minimum configuration 0 60 kVA Maximum configuration 1 10 kVA Btu output ship configuration 2013 Btu hr 590 watts Btu output full configuration 3610 Btu hr 1056 wa...

Страница 18: ...tude 0 to 915 m 3 000 ft Server on 10 C to 32 C 50 F to 90 F altitude 915 m 3 000 ft to 2 134 m 7 000 ft Server on 10 C to 28 C 50 F to 83 F altitude 2 134 m 7 000 ft to 3 050 m 10 000 ft Server off 5...

Страница 19: ...ategory 2005 F 0 00089 Product Category 2007 C 0 00089 Product Category 2011 L 0 00089 X5675 3 06 GHz Product Category 2005 F 0 00059 Product Category 2007 C 0 00059 Product Category 2011 L 0 00059 X5...

Страница 20: ...about IBM and non IBM devices adapters software and network operating systems supported with x3500 servers visit http www ibm com servers eserver serverproven compat us Contact your IBM representative...

Страница 21: ...is connected with ServeRAID BR10i controller through two miniSAS cables ServeRAID BR10i is standard offering on system The DVD is SATA attached External SAS attachment In the configurations where an e...

Страница 22: ...tion it can also be installed in the deeper NetBAY42 ER If you choose not to use an IBM rack the cabinet must meet EIA 310 D standards for mounting flanges and hole clearances with front to rear mount...

Страница 23: ...te control password functions provide controls of who has access to the data and server setup program on the server It is a customer s responsibility to ensure that the server is secure to prevent sen...

Страница 24: ...talled part or feature assumes the remainder of the warranty period for the replaced part or feature An IBM part or feature added to a machine without replacing a previously installed part or feature...

Страница 25: ...ilability a CRU will be shipped for next business day NBD delivery IBM specifies in the materials shipped with a replacement CRU whether a defective CRU must be returned to IBM When return is required...

Страница 26: ...Under IWS warranty service will be provided with the prevailing warranty service type and service level available for the IWS eligible machine type in the servicing country and the warranty period ob...

Страница 27: ...uding hardware software and services from both IBM and other manufacturers or vendors Offerings for all customer segments small medium and large enterprise rates terms and availability can vary by cou...

Страница 28: ...dows are registered trademarks of Microsoft Corporation in the United States other countries or both Linux is a registered trademark of Linus Torvalds in the United States other countries or both Othe...

Отзывы: