Drive Bays 

The x3400 M2 contains either 

11

 drive bays (in 2.5-inch models) or 

7

 bays (in 3.5-inch) models. 2.5-inch 

models support small form-factor (SFF) 

hot-swap SAS 

drives. 3.5-inch models support 

four hot-swap 

SAS 

or

 SATA II

 drives, or 

simple-swap SATA II

 drives. In addition, there are 

three 5.25-inch

 bays. 

An internal 

full-high

 tape drive can be installed using 

two

 of the 5.25-inch drive bays; alternatively, an 

internal 

half-high

 tape drive can be installed using 

one

 of the 5.25-inch drive bays. The tape drive must 

have a 

USB 2.0

 interface. 

A half-high DVD-ROM drive with a SATA interface ships standard in the other 5.25-inch bay. An external 
USB floppy drive may be used, if needed. 

Hot-swap drives may be inserted or removed through the front of the server without powering off the 
system. Simple-swap drives may also be installed and removed through the front, but requires powering 
off the server first. 

For still more storage, a direct-attach, NAS or SAN external expansion option can be added, using an 
optional controller.

 

 

Disk/Tape Controllers 

All 

hot-swap

 x3400 M2 models include an integrated hardware-based IBM 

ServeRAID-BR10i SAS/SATA 

controller

. This controller supports up to eight internal SAS or SATA drives. (Simple-swap models use the 

SATA support incorporated in the system chipset.) 

The integrated 

ServeRAID-BR10i

 controller offers 

hardware

 

RAID-0

/

1/1E

 support. The controller provides 

data transfer speeds of up to 

3Gbps

6

 per SAS port on an 8-lane 2.5 Gbps PCIe card. It supports both 

SAS and SATA HDDs, as well as Solid-State Drives (SSDs) and tape drives. 

The x3400 M2 also supports full 

RAID-0/1/10/1E/5/6

 support using the optional 

ServeRAID-MR10i 

card. It 

also offers higher performance, due to the 

256MB battery-backed onboard cache

The x3400 M2 also supports hardware based full-disk encryption with 

RAID-0/1/10/1E/5/6

 support using 

the optional 

ServeRAID-MR10is Vault

 card.  

For external storage, the 

ServeRAID-MR10M

 controller enables connection to up to four IBM System 

Storage EXP3000 SAS expansion units (48 HDDs total). It provides RAID-0/1/10/5/50 support and 

256MB

 

of onboard cache.

 

 

Internal Backup 

The x3400 M2 supports several internal 

tape backup 

options. Supported technologies include: 

 

DDS-5

 (half-high) 

 

DDS-6

 (half-high) 

 

GoVault internal dock

 (half-high) 

 

LTO-3 Ultrium

 (half-high) 

 

LTO-4 Ultrium

 (half-high)

 

 

High-Performance Adapter Slots 

The x3400 M2 provides six adapter slots in all, including 

one x16

 (“by 16”) physical/

x8

 electrical 

PCIe 

(PCI Express)

 

Gen 2

 

full-length/full-height

 adapter slot (

Slot 2

).

 

This means that although the slot runs 

at 

x8 Gen 2

 speeds (

8GBps

), it can accept a x16 Gen 2 adapter in the slot.

 

It is also capable of 

supporting 

x1/x4/x8

 adapters at full speed. In addition to this slot, the x3400 M2 also includes two 

x8 

physical/x8 electrical

 

Gen 2

 slots (

8GBps

), two 

x8 physical/x4 electrical

 

Gen 2 

slots (

4GBps

), and one 

33MHz legacy PCI 

slot. As part of a configure-to-order (CTO) build two choices of PCIe riser card can be 

added, with either 

two 133MHz PCI-X

 slots or one PCIe 

x8 physical/x4 electrical Gen 1

 slot (

2GBps

). 

Slot

 

1

 is a 

half-length/full-height PCIe 

slot; 

slots 2, 3, 4 

and

 5

 are 

full-length/full-height 

PCIe slots, 

and 

Slot 6

 is a 

half-length/full-height 33MHz 

legacy

 PCI 

slot. The 

PCI-X

 riser contains two 

full-

length/full-height 

slots (

5

 and 

6

). 

PCI Express

 is a high-performance, low-latency, next-generation serial I/O bus that is rapidly replacing 

the older parallel PCI and PCI-X buses. A 

x16

 PCIe Gen 2 adapter offers approximately 

sixteeen times

 

the maximum throughput of a 133MHz PCI-X adapter

7

. (A 

x1

 Gen 1 adapter offers throughput similar to a 

66MHz

 PCI-X slot.)

 

 

Dual-Port Gigabit Ethernet Controller 

The x3400 M2 includes 

one dual-port

 integrated 

Broadcom 5709C 

Gigabit Ethernet controller for up to 

10X higher maximum throughput than a 10/100 Ethernet controller, as well as support for 

PXE 2.0 

6

 Data transfer rates depend on many factors and are often less than the maximum possible. 

7

 Actual throughput will depend on the adapter vendor’s implementation. 

Содержание x3400 M2 7836

Страница 1: ...drives with a total capacity of up to 4 0TB For additional performance and high availability the hot swap x3400 M2 models include an IBM ServeRAID BR10i controller providing RAID 0 1 1E support Addit...

Страница 2: ...of low cost battery backed cache to enable high performance hardware RAID support and allows the x3400 M2 to offer eight RAID levels RAID 0 1 10 1E 5 50 6 and 60 The optional ServeRAID MR10M controll...

Страница 3: ...P SHA 1 AES and a firmware firewall Temperature controlled fans adjust to compensate for changing thermal characteristics At the lower speeds they draw less power and suffer less wear Equally importan...

Страница 4: ...ry may be clocked at 1066MHz or 800MHz Note If only one processor is installed only the first six DIMM slots can be used Adding a second processor not only doubles the amount of memory available for u...

Страница 5: ...x3400 M2 offers an additional but mutually exclusive level of IBM Active Memory protection online memory mirroring Memory mirroring works much like disk mirroring The total memory is divided into two...

Страница 6: ...support using the optional ServeRAID MR10is Vault card For external storage the ServeRAID MR10M controller enables connection to up to four IBM System Storage EXP3000 SAS expansion units 48 HDDs tota...

Страница 7: ...nt airflow paths provide highly effective system cooling for the x3400 M2 known as Calibrated Vectored Cooling The server includes three hot swap fans plus another in the power supply The system conta...

Страница 8: ...ferings everything is done externally via cabling no special adapters are required Extensive System Support Features The IBM services and technical support portfolio provides world class consistent hi...

Страница 9: ...upport by phone and via the Web Support options include links to forums newsgroups problem submission online shopping support service offerings device drivers for all IBM product lines software downlo...

Страница 10: ...y that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Text...

Страница 11: ...the availability of the data SAS and SATA ServeRAID controllers offer enhanced performance due to onboard processors and cache Because IBM ServeRAID controllers can help significantly improve data tr...

Страница 12: ...e Bays DVD ROM Drive Locking Drive Covers Hexagonal Ventilation Holes 2 USB 2 0 Ports behind door 2 USB 2 0 Ports internal IMM 4 3 5 inch or 8 2 5 inch HDD Bays 3 5 25 inch Drive Bays CPU 2 Fans Fixed...

Страница 13: ...No Memory mirroring supported of DIMM sockets reserved for mirroring Yes 12 6 per processor of drive bays total available 11 10 14X 14Y 34X 34Y 52X 52Y 7 6 12X 12Y 22X 22Y 24X 24Y 32X 32Y 42X 42Y 44X...

Страница 14: ...n 1 physical x4 Gen 1 electrical slots 2GBps None standard 1 optional via CTO by adding a PCIe extender card of PCI X 133 slots 1GBps None standard 2 optional via CTO by adding a PCI X extender card o...

Страница 15: ...rdware based RAID 0 data hot swap models Fast communications Integrated dual port Gigabit Ethernet controller standard supporting Jumbo Frames TOE and optionally iSCSI and RDMA requires license key tw...

Страница 16: ...for which each server is best suited 12 The x8 x8 Gen 2 slots can accept x1 x4 or x8 adapters running at x1 x4 or x8 throughput respectively 13 The x8 x4 Gen 2 slots can accept x1 x4 or x8 adapters ru...

Страница 17: ...change specifications or other product information without notice References in this publication to IBM products or services do not imply that IBM intends to make them available in all countries in w...

Отзывы: