background image

Identifying a failed power supply

Each power supply unit uses an LED that indicates whether the unit is working as expected. Figure 1
describes the LEDs that are displayed by the power supply units for the appliance:

The following table indicates the potential problems that can occur with the power supply and suggests
actions for you to use to correct the detected problems:

Table 1. Power supply LED combinations for detecting potential problems

AC

DC

Error

Description

Action

Notes

Off

Off

Off

No AC power is going to
the appliance, or there is a
problem with the AC
power source.

1.

Check the AC power
that is going to the
appliance.

2.

Make sure that the
power cord is
connected to a
functioning power
source.

3.

Turn off the appliance
and then turn the
appliance back on.

4.

If the problem
remains, replace the
power supply.

This condition is normal
when no AC power is
present.

Figure 1. Power supply LEDs

3

Содержание V.90 PCI

Страница 1: ...tems Safety Notices provided in the IBM Media Terms and Conditions CD that is included with your appliance model Note The illustrations in this document might differ slightly from your appliance model Supported appliances The following table lists the appliance models that are supported by the instructions in this document Product Model IBM Part Number IBM Security Access Manager AMP 5100 97Y0608 ...

Страница 2: ...t from the device ensure that all power cords are disconnected from the power source CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contac...

Страница 3: ...ect the detected problems Table 1 Power supply LED combinations for detecting potential problems AC DC Error Description Action Notes Off Off Off No AC power is going to the appliance or there is a problem with the AC power source 1 Check the AC power that is going to the appliance 2 Make sure that the power cord is connected to a functioning power source 3 Turn off the appliance and then turn the...

Страница 4: ... power to the appliance Off On Off The power supply is faulty Replace the power supply N A Off On On The power supply is faulty Replace the power supply N A On Off Off The power supply is not fully seated 1 Reseat the power supply 2 If a power channel error LED on the system board is not illuminated replace the power supply This condition usually indicates that a power supply is not fully seated O...

Страница 5: ...ower supply from the bay as shown in Figure 2 Important During normal operation each power supply bay must contain either a power supply or a power supply blank for proper cooling 2 Slide the AC power supply into the bay until the retention latch clicks into place Make sure that the power supply connects firmly to the power supply connector 3 Connect the power cord for the new AC power supply to t...

Страница 6: ...lectrical outlet What to do next Make sure that the AC power LED and the DC power LED on the AC power supply are illuminated which indicates that the power supply is operating correctly The two power LEDs are to the left of the power cord connector Figure 3 Identifying the power cord connectors First edition August 2013 Copyright IBM Corporation 2013 2015 US Government Users Restricted Rights Use ...