background image

Note: If a RESET is issued before the
drive comes ready the power on
sequence will start again. In all other
cases when a RESET is issued the
present state of the motor is not altered.

WARNING: This disk drive can be
damaged by Electro-Static Discharge,
please  follow recommended ESD
procedures before unpacking or
handling the drive. Ask your Dealer for
details if you need assistance.

Note: BATS is the abbreviation for
Basic Assurance Tests. Start-up
sequence 

spins up the spindle motor,

uploads code, performs BATS2 (verifies
read/write hardware), resumes
“Reassign in Progress” operations, and
more.  For more information on the
start-up sequence, refer to the Ultrastar  
9LP & 18XP Interface Specification.

Mechanical Specifications

Weight
9.11GB Approx 1.26 pounds (0.57 Kg)
18.22GB Approx 2.04 pounds (0.93 Kg)

Dimensions

Inches

S.I.Metric

Height

9.11GB

1.00 in

25.4 mm

18.22GB

1.63 in

42.0 mm

Width

4.00 in

101.85 mm

Depth

5.75 in

147.0 mm

Vibration and Shock

Operating/Nonoperating Vibration
Due to the complexity of this subject we
recommend that users contact the
Distributor to discuss how to perform
the required measurements if they
believe this to be an area which
requires evaluation.

Operating Shock
No permanent damage will occur to the
drive when subjected to a 10 G half
sine wave shock pulse of 11
milliseconds duration. The shock pulses
are applied in each of three mutually
perpendicular axis, one axis at a time.

Nonoperating Shock
Translational Shock
No damage will occur if the unpackaged
drive is subjected to a square wave
shock less than 35 Gs applied to all
three axis for  a period of 20
milliseconds, one direction at a time.
Additionally, no damage will occur if the
unpackaged 9.11GB drive is not
subjected to an 2 millisecond half sine
wave shock greater than 150Gs applied
to all three axis, one direction at a time.
Additionally, no damage will occur if the
unpackaged 18.22GB drive is not
subjected to a 2 millisecond half sine
wave shock greater than 140Gs applied
to all three axis, one direction at a time.
For the 1.0” models, no degradation in
A-weighted idle sound power will occur
if the unpackaged drive is limited to a 2
milliseconds half sine pulse shock of
150Gs or less applied in the axial
direction (z axis), or 300Gs or less
applied in radial direction (x-y plane).

For the 1.6” models, no degradation in
A-weighted idle sound power will occur
if the unpackaged drive is limited to a 2
milliseconds half sine pulse shock of
70Gs or less applied in the axial
direction (z axis), or 150Gs or less
applied in the radial direction (x-y
plane).  The average A-weighted idle
sound power will increase by 0.3 Bels if
the unpackaged drive is subjected to a
2 milliseconds half sine pulse shock of
110Gs applied in the axial direction (z
axis), or 210Gs applied in the radial
direction (x-y plane).

Rotational Shock
The  actuator will remain latched in the
disk landing zone if the unpackaged
drive is subjected to a 2ms  half sine
pulse shock of 15,000 radians per
second squared or less applied to all
three axis, one direction at a time. 

Start and Stop Times

Time

Nominal

Maximum

Nominal

Maximum

Models

9.11GB

9.11GB

18.22GB

18.22GB

Power Up

2.5

3.0

2.5

3.0

Start-up

17

45

16.5

45

Spin-up

11

30

10.5

30

Spindle Stop

15

15

15

15

All times in seconds

Bring-up Sequence Times and Stop Time

Reset Init 

and Test of 

Controller

Enable 

SCSI Bus

Power On

Auto Start function enabled
or Start Unit command issued at this time.

File Ready to accept Read and Write commands.

Power-up

Start-up Sequence

Spin-up

Init. Servo 

BATS2

Complete 

Reassigns etc.

Содержание Ultrastar 9LP

Страница 1: ...multitasking applications M M Low command overhead M M Read ahead caching M M Improved data throughput M M ECC on the fly EOTF M M Industry standard mounting M M Ease of installation M M Predictive F...

Страница 2: ...2 4 6 8 20 22 24 26 28 30 32 Enable Active Termination 5V 2 SCSI Address Not Used Blank Ground External Activity LED Write Protect Auto Start Delay Disable Sync Negotiations Disable SCSI Parity Disabl...

Страница 3: ...Delay Start Start Multiplier off off Yes 0 off on No N A on off Yes 10 on on No N A Auto Startup Modes selectable by Auto Start Delay Pin Combinations PACKAGING The drive must be protected against ele...

Страница 4: ...pacity blocks block bytes drive 512 18 351 959 040 35 843 670 514 18 283 057 100 35 570 150 520 18 132 478 000 34 870 150 522 18 102 432 780 34 678 990 524 18 098 346 920 34 538 830 528 18 177 133 920...

Страница 5: ...ment 80 pin SCA 2 models use an AMP connector PN 5 917593 9 that is compatible with the specification of Single Connector Attachment for Small SCSI Disk Drives SFF 8046 It can transfer data in both 8...

Страница 6: ...power SCSI Bus Termination Power Short Circuit Protection The ANSI SCSI specification recommends for devices that optionally supply TERMPWR to include current limited protection for accidental short c...

Страница 7: ...if the unpackaged 9 11GB drive is not subjected to an 2 millisecond half sine wave shock greater than 150Gs applied to all three axis one direction at a time Additionally no damage will occur if the u...

Страница 8: ...emperature must not be exceeded at the worst case drive and system operating conditions with the drive randomly seeking reading and writing Reliability temperatures must not be exceeded at the nominal...

Страница 9: ...trademark of AMP Incorporated Other company product and service names may be trademarks or service marks of others Produced by European SIT Lab International Business Machines Corporation 1997 This da...

Отзывы: