Chapter 1. Start Service
1-15
Drive Error Codes
00F8
Sensor error #7.
During blink check, a Y
encoder sensor error was
detected.
CHK 00F8
1.
Cycle the power and try again.
2.
Replace the Library Control Blade (page 9-8).
3.
Replace the Accessor assembly (page 9-23).
4.
Replace the Accessor Flat Cable Plate assembly (page 9-28).
5.
Replace the Back Board assembly (page 9-37).
6.
Replace the TS3400 Tape Library chassis (page 9-44).
00F9
Sensor error #8.
During blink check, an X
encoder sensor error was
detected.
CHK 00F9
00FA
Sensor error #9.
During blink check, an
I/O slot sensor error was
detected.
CHK 00FA
00FB
Sensor error #10.
During blink check, a
magazine (Upper) sensor
error was detected.
CHK 00FB
00FC
Sensor error #11.
During blink check, a
magazine (Lower) sensor
error was detected.
CHK 00FC
00FD
Sensor error #12.
During blink check, an X
origin sensor error was
detected.
CHK 00FD
Table 1-2. Drive error codes
Code (H)
Description
Panel
indication
Action Required
0200
Invalid data was sent to
Drive #1.
NAK was detected.
CHK 0200
1.
Confirm the drive connection.
2.
Cycle the power and try again.
3.
Replace the Library Control Blade (page 9-8).
4.
Replace the drive canister (page 9-11).
5.
Replace the Drive Docking Card (page 9-19).
6.
Replace the Back Board assembly (page 9-37).
7.
Replace the TS3400 Tape Library chassis (page 9-44).
0201
A timeout error occurred
while waiting for response
from Drive #1.
CHK 0201
0203
Drive #1 is disconnected.
CHK 0203
0205
Drive #1 is busy.
CHK 0205
0206
Drive #1 failed to execute
a command because drive
could not be mounted.
CHK 0206
Table 1-1. Library error codes (continued)
Code (H)
Description
Panel
Indication
Action Required
Содержание TS3400
Страница 1: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03 ...
Страница 2: ......
Страница 3: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03 ...
Страница 6: ...iv TS3400 Tape Library Maintenance Information ...
Страница 14: ...xii TS3400 Tape Library Maintenance Information ...
Страница 52: ...1 36 TS3400 Tape Library Maintenance Information ...
Страница 84: ...3 14 TS3400 Tape Library Maintenance Information ...
Страница 92: ...4 8 TS3400 Tape Library Maintenance Information ...
Страница 106: ...5 14 TS3400 Tape Library Maintenance Information ...
Страница 109: ...Chapter 6 Installing the Library 6 3 Figure 6 1 Components removed to reduce weight a34z0177 ...
Страница 194: ...8 40 TS3400 Tape Library Maintenance Information ...
Страница 260: ...11 8 TS3400 Tape Library Maintenance Information ...
Страница 266: ...12 6 TS3400 Tape Library Maintenance Information ...
Страница 274: ...B 2 TS3400 Tape Library Maintenance Information ...
Страница 293: ......
Страница 294: ... Part Number 45E5263 Printed in USA GA32 0572 03 1P P N 45E5263 ...
Страница 295: ...Spine information IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 ...