v
Hot-swap
fan
bays:
The
EXP100
has
two
interchangeable
hot-swap
and
redundant
fan
units.
These
two
fan
units
are
located
in
the
hot-swap
fan
bays.
Each
fan
unit
contains
two
fans.
If
one
fan
unit
fails,
the
second
fan
unit
continues
to
operate.
You
must
install
both
fan
units
to
maintain
proper
cooling
within
your
expansion
enclosure,
even
if
one
fan
unit
is
not
operational.
The
fan
CRUs
have
locking
latches
that
secure
them
to
the
fan
bays.
You
must
unlock
the
latches
before
you
can
remove
the
fan
from
the
expansion
enclosure.
When
you
replace
a
fan,
you
must
align
it
properly
for
the
side
in
which
it
is
being
replaced.
See
v
ESM
bays:
The
EXP100
has
two
hot-swappable
ESMs.
The
ESMs
are
located
in
the
ESM
bays.
The
ESMs
provide
a
1.5
Gbps
Serial
ATA
interface
to
the
drives
and
monitor
the
overall
status
of
the
expansion
enclosure.
Each
ESM
has
two
SFP
module
connector
Fibre
Channel
ports
that
you
use
to
connect
your
expansion
enclosure
to
the
DS4000,
or
to
connect
two
or
more
EXP100
units
together.
The
ESMs
provide
redundancy
when
both
of
them
are
configured
into
redundant
Fibre
Channel
loops.
Attention:
See
for
more
information
about
ESM
redundancy
and
failover
configurations.
After
you
remove
an
ESM,
wait
70
seconds
before
reseating
or
replacing
the
ESM.
Failure
to
do
so
may
cause
undesired
events.
The
ESMs
have
locking
latches
that
secure
them
to
the
ESM
bays.
You
must
unlock
the
latches
before
you
can
remove
the
ESM
from
the
expansion
enclosure.
v
Hot-swap
power
supply
bays:
The
EXP100
has
two
hot-swap
and
redundant
power
supplies.
The
power
supplies
are
located
in
the
hot-swap
power
supply
bays.
You
must
install
both
power
supplies
in
your
expansion
enclosure,
even
if
one
power
supply
is
not
operational.
The
power
supplies
have
locking
levers
that
secure
them
to
the
power
supply
bays.
You
must
unlock
the
levers
before
you
can
remove
the
power
supply
from
the
expansion
enclosure.
The
power
supplies
are
interchangeable,
but
you
must
mount
the
lever
on
the
interior
corner
of
the
power
supply
CRU
(that
is,
when
viewed
from
the
back
of
the
unit,
the
power
supply
CRU
in
the
left
power
supply
bay
has
the
lever
mounted
on
the
right
side,
and
the
one
in
the
right
power
supply
bay
has
the
lever
mounted
on
the
left
side).
See
1 Gb/s
2 Gb/s
X10
X1
T
r
ay Number
Conflict
Hot-swap fan bays
Hot-swap power
supply bays
Power supply locking levers
Fan latches
ESM latches
ESM bays
Figure
2.
Hot-swap
fan,
ESM,
and
power
supply
bays
16
IBM
TotalStorage
DS4000
EXP100
Storage
Expansion
Enclosure:
Installation,
User’s
and
Maintenance
Guide
Содержание TotalStorage EXP100
Страница 2: ......
Страница 10: ...viii IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 12: ...x IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 18: ...xvi IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 132: ...106 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 148: ...122 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 160: ...134 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 162: ...136 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 164: ...138 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 180: ...154 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 187: ......
Страница 188: ... Part Number 39M5947 Printed in USA GC26 7694 01 1P P N 39M5947 ...